Warning and cautions:
1.1 The multi-mounted split unit adopts double separated cooling systems (A and B) that are not connected together. If
the refrigerant leaks, the leaking system of them must be determined. So we can solute the abnormality. And refill the
system that lacks refrigerant. It will influenc e the eff ect if t he A and B syst ems ar e wr ongly estimated.
1.2 The maximum length of single connecting pipe is 7m. And the units c an't run normally if the pipe is over required
length.
1.3 Fill refrigerant in accordance w ith the diagram below if the connecting pipe is over 5m.
Length 5m 7m ----
5HIULJHUDQWFKDUJH 12 J 
9DFXXPSXPSLQJRIWKHV\VWHP
9DFXXPSXPSLQJLVWRPDLQO\GUDZRXWUHVLGXDODLUDQGZDWHULQWKHDLUFRQGLWLRQHUUHIULJHUDQWV\VW HP
*HQHUDOO\YDFXXPSXPSLVFRQQHFWHGDWWKHSURFHVVLQJSRUWRIWKHZD\VWRSYDOYHLQWKHRXWGRRUXQLW
7KHV\VWHPYDFXXPGHJUHHLVUHTXLUHGWREHEHORZ3D
5HIULJHUDWLQJF\FOHGLDJUDP
Outdoor unit
Heat exchanger
B indoor unit
Heat exchanger
A indoor unit
Heat exchanger
A Compressor
A 4-way valve
B 4-way valve
B Compressor
Capillary tube
Capillary tube
Capillary tube
Capillary tube
3- way valve
Cooling
Heating
3- way valve
2- way valve
2- way valve
Domestic Air Conditioner
Model: H2SM-14HC03/R2
H2SM-18HC03/R2
42

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier H2SM-14HC03/R2 and is the answer not in the manual?

Haier H2SM-14HC03/R2 Specifications

General IconGeneral
BrandHaier
ModelH2SM-14HC03/R2
CategoryAir Conditioner
LanguageEnglish

Related product manuals