H2SM-(9+12)HEK03/R2
Funcitions and Control
Domestic Air Conditioner
18
Conditions for ending defrosting: It will restore to the heating operation from the defrosting 
operation as long as any of the following conditions is met. The temperatures on both outdoor heat 
exchangers are above 7 degrees for consecutive 80 seconds.
The temperatures on both outdoor heat exchangers are above 5 degrees for consecutive 12 
seconds.
The defrosting operation has lasted 9 minutes.
The starting conditions and control process for the double-unit are same as that for single-unit 
defrosting, the only difference is that the activation of compressor B lags that of compressor A.
5.2.11 Alarming operation
 :KHQWKHZKROHXQLWLVLQQRUPDORSHUDWLRQWKHDODUPOLJKWLVDOZD\VRQEXWGRHVQRWÀDVK
When the outdoor temperature sensor short-circuited or disconnected, the outdoor fan always 
operates at the medium speed and will restore automatically after the sensor comes to normal.
When the temperature sensors on the pipes A and B short-circuited or disconnected, the double 
unit will not carry out defrosting operation. During heating, this signal is sent to the indoor unit, but no 
sending for other operating conditions. When sent to the indoor unit, the whole unit stops. The signal is 
sent to the indoor unit which coil is operating abnormally, and the corresponding indoor unit indicates 
trouble.
When the temperature sensor short-circuited or disconnected or the current transformer fails, the 
DODUPOLJKWÀDVKHVLQWKHIROORZLQJPDQQHUZKHQWKHFXUUHQWWUDQVIRUPHUIDLOVWKHVLJQDOLVVHQWWRWKH
indoor unit that operates abnormally, and the corresponding indoor unit indicates trouble.