9
Don’t make 
heat
The air 
conditioner
can
refrigerate
but can’t 
make heat 
Outdoor P.C. Boardǃ4 way valve 
coilǃ  4 way valve body. Examine
the CN204 at Outdoor P.C. Board 
and watch if there is 220V 
voltage .If there doesn’t have we 
can judge that the P.C. Board is 
bad. If there has, we need to 
connect and check the whether the 
4 way valve coil and the 4way 
valve body have been damaged .
Outdoor P.C. 
Boardǃ4way
valve coilǃ 4 
way valve 
bodyǃ
avometer. 
Little split 
unit of 
frequency
conversion
10 Show error 
code E8 
The
machine
doesn’t
work and 
shows error 
code E8 
Multimeter negative generatorǃ
indoor P.C. board  ǃconnecting and 
inserting lines .Check if the 
Multimeter negative generator is 
plane and the grounding (CF) is 
touching well, then examine not 
only whether the indoor P.C. Board
and control board    have been 
damaged or not but also the 
connecting lines are good. 
Multimeter
negative
generatorǃ
indoor P.C. 
Boardǃ
control
board ǃ
grounding
(CF)ǃ
avometer. 
The series 
of
frequency
fixed 
cabinet
type
11 Can’t start 
The air 
conditioner
can’t start 
Transformerǃindoor
microcomputer plateǃfuse. Check
if the transformer has been 
burned. power wave filterǃ
LX102.Check whether the fuse 
and indoor microcomputer plate 
have been damaged. 
Transformerǃ
power wave 
filterǃindoor 
microcompute
r plateǃfuseǃ
avometer. 
The series 
of
frequency
fixed 
cabinet
type
12
Show error 
code F11 
When the 
air
conditioner
has run 
about
5minutes
the indoor 
unit shows 
the error 
code  F11. 
The system pressureǃoutdoor P.C. 
BoardǃPower source voltageǃ
power modelǃthe connecting lines 
of compressor. The cause is that 
protective action has been taken 
when it runs with large burden, 
there is more refrigerant than it 
should be .Examine the outdoor 
P.C. BoardǃPower source voltageǃ
power model and see whether they 
have been damaged and the 
connecting lines touch well, if not, 
adjust it to be normal. 
outdoor  P.C. 
BoardǃPower 
source
voltageǃpower 
model . 
The
machine of 
frequency
conversion
split unit
Air Conditioner