H1U12TAAOUT H1U18TAAOUT
Model H1U09TAAOUT H1U09FAAOUT H1U24TAAOUT
H1U12FAAOUT
H1U18FAAOUT
Connecting wiring 4G1.0mm² 4G1.0mm² 4G1.0mm²
Power cable 3G1.0mm² 3G1.5mm² 3G2.5mm²
item Circuit breaker Earth leakage breaker
Phase
Overcurrent protector
rated capacity (A)
Model
Switch breaker(A) Switch breaker(A) Leak current(mA)
H1U09TAAOUT H1U12TAAOUT
H1U09FAAOUT H1U12FAAOUT
1 20 15 20 30
H1U18TAAOUT H1U18FAAOUT
H1U24TAAOUT
H2U14MAAOUT H2U18MAAOUT
H2U14TAAOUT H2U18TAAOUT
1 25 20 25 30
ceramic type of T 25A/250V.
.
The explosion-proof breaker of the air conditioner should be all-pole switch. The distance between its two contacts should not be no
A explosion-proof breaker must be installed.
FOR
FOR
H1U09TAAOUT H1U12TAAOUT
FOR
H1U24TAAOUT
H1U18FAAOUT
H1U18TAAOUT H1U09FAAOUT
H1U12FAAOUT
Outdoor unit
Outdoor unit
1(N)
2(L)
POWER
TO Indoor unit A
TO Indoor unit B Power
To Indoor unit
To Indoor unit
POWER
Room A Power supply
Room B
26
H2U14MAAOUT
H2U18MAAOUT
H2U14TAAOUT
H2U18TAAOUT
H2U14MAAOUT
H2U18MAAOUT
H2U14TAAOUT
H2U18TAAOUT