Model: HC17SF10RB/HC27SF10RW/B
12
Issue   2014-3-10 
Rev.  Ref1403S005V0
6-2. Normal phenomena   
Problems Reasons   Solving methods 
Compressor 
can not be 
started 
1. Cable broken. The contact of plug, 
socket, and cable is broken. 
2.    The voltage is too low ,and lower than 
the rated voltage115V 
3. The knob of the thermostat is at “0” 
position (When ambient temperature is 
higher than “30” degree centigrade ,set the 
knob to “1-2” position; When ambient 
temperature is between “16-30” degree 
centigrade ,set the knob to the “3-4” 
position, and when it lower than “16” 
degree centigrade ,set the knob to the 
“4-5”position) 
4.    The thermostat is out of order 
 
1. Check and contact normally, or 
else, change damaged part. 
2. Use until the voltage rise to the 
rated voltage ,or attach the voltage 
stabilizer 
3 Set the knob of the thermostat to 
the suitable position 
4. Change the thermostat 
 
Compressor 
starts too 
frequently 
1. The distance between protection and the 
heater is too close   
2. The door gasket does not seal enough or 
the cabinet’ heat insulation is not good   
3. The setting of the thermostat knob is too 
low  
1.  Adjust the overload adjustable 
screw, and increase their 
distance. 
2.  Check and repair the cabinet or 
the door gasket.(check if the 
door gasket flashed and repair 
it )   
3.  Set the knob of the thermostat 
to the suitable position   
Compressor 
runs without 
stopping 
1.  The refrigerant leakage or insufficient 
2.  The refrigerant is superfluous 
3.  The condenser is dirty 
4. The refrigerator insulation layer is 
destroyed, and the door gasket’ sealing 
is bad. 
1.  Check and find the leakage 
point, let out the refrigerant, 
then meld it and vacuumed and 
fill the refrigerant again. 
2.  Let out the suitable refrigerant 
3.  Make sure the condense clean 
4.  the door gasket.(check if the 
door gasket flashed and repair 
it )