Refrigerator
SERVICE MANUAL
MODEL:HRFZ-250DAA
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It
dose not contain warnings and cautions to advice non-technical individuals of potential dangers in attempting to service a product.
Product powered by electricity should by serviced or repaired only by experienced professional technicians. Any attempt to service
or repair the product or products dealt with in this service information by anyone else could result in serious injury or death.
WARNING

Questions and Answers

  • M
    mwrightAug 8, 2025
    Why does my Haier HRFZ-250DAA Refrigerator compressor start too frequently?
    • A
      Amy KruegerAug 8, 2025
      Frequent compressor starts in your Haier Refrigerator can occur for several reasons. The distance between protection and the heater might be too close, so adjust the overload adjustable screw to increase their distance. The door gasket might not seal well, or the cabinet's heat insulation may be poor; inspect and repair the door gasket or cabinet, checking for flashes on the door gasket. Poor condenser heat dissipation, leading to compressor overload, can also be a cause; clean the condenser, especially the dust on both sides of the cabinet. Lastly, the thermostat knob might be set too low; adjust the thermostat knob accordingly.
  • J
    Jocelyn MosleyAug 23, 2025
    What to do if the Haier HRFZ-250DAA compressor can’t be started?
    • E
      Emily CoxAug 23, 2025
      If your Haier Refrigerator's compressor won’t start, several issues could be the cause. First, check the fuse for a short circuit and replace it if necessary. Inspect the cable, plug, and socket for any breaks or contact issues, repairing or replacing damaged parts. If the voltage is too low (below 220V, but within 187V to 242V), wait until it rises or attach a voltage stabilizer. Ensure the thermostat knob isn't at the “MIN” position; adjust it accordingly. If these steps don't work, the thermostat, start relay, or thermal protection might be faulty and require replacement. Finally, a broken wire in the motor starting coil or operation coil could be the problem; measure it with a meter, and if there's a short circuit, the compressor needs changing.

Summary

Chapter 2 Product Feature

2-1. Specifications

Detailed technical specifications of the refrigerator model.

Chapter 3 Disassembly

Chapter 7 Trouble shooting

7-1. phenomena and solving

Common refrigerator problems and their solutions.

Chapter 8 Quick check

8-1.No cooling

Troubleshooting guide for lack of refrigerator cooling.

8-2.Compressor no start

Troubleshooting guide for compressor startup failure.

8-3.Poor cooling

Troubleshooting guide for insufficient or poor cooling performance.

8-4.Noisy

Troubleshooting guide for unusual refrigerator noises.

Haier HRFZ-250DAA Specifications

General IconGeneral
ModelHRFZ-250DAA
CategoryRefrigerator
InstallationFreestanding
Total Capacity250 liters
Cooling TechnologyDirect Cool
Noise Level42 dB
Energy Efficiency ClassA+
RefrigerantR600a
ColorWhite
Voltage220-240V
Frequency50 Hz
Star Rating4 stars