List of error code: 
Error display 
Abnormity mode 
Po
we
r 
Ti
m
er 
Run
ning
Ind
oor
Out
door
Autom
atic 
restore
Possible reason 
Abnormity of indoor 
thermistor 
★ ■  ■ *    * 
1. Inserter does not contact well or 
control board is not good. 
Abnormity of 
thermal conversion 
thermistor 
★ □  □ *    * 
1. Inserter does not contact well or 
control board is not good. 
Abnormity of 
defrosting thermistor 
□ □  ★  *  * 
1. Inserter does not contact well or 
control board is not good. 
Abnormity of 
discharging 
thermistor 
★ □  ■  *  * 
1. Inserter does not contact well or 
control board is not good. 
Abnormity of 
control board 
thermistor 
□ ■  ★  *  * 
1. Inserter does not contact well or 
control board is not good. 
Abnormity of 
module thermistor 
□ ★  □  *  * 
1. Inserter does not contact well or 
control board is not good. 
Abnormity of 
outdoor thermistor 
□ ★  ■  *  * 
1. Inserter does not contact well or 
control board is not good. 
*    
1. There is great interference source 
around 
Transmission 
abnormity 
■ ■  ★ 
 *   
2. Incorrect wire connection or control 
board is not good. 
Compressor running 
abnormity 
★ ■  □  *   
1. Check if compressor shaft is seized. 
2. Whether power module is damaged 
Overhigh 
discharging 
temperature 
protection 
■ ★  ■  *   
1. Whether system gas is insufficient or 
charged gas is too much. 
2. Whether system voltage is too high 
(above242V) or too low (below 
187V) 
3. Whether capillary tube is blocked. 
4. Whether sensors or control board 
components are abnormal. 
5. Whether the indoor/outdoor ambient 
temperature is too high. 
AC current 
protection 
★ ★  ■  *   
1. Whether system is charged too many 
gases. 
2. Whether voltage is too low (below 
187V). 
3. Whether CT or control board 
component is abnormal. 
DC current 
protection 
★ ★  □  *   
1. Whether compressor shaft is seized. 
2. Whether power module is damaged. 
3. Whether system voltage is too high 
(above242V) or too low (below 
187V) 
Insufficient current 
protection 
■ ★  □  *   
1. Whether voltage is too low. 
2. Whether control board is damaged. 
32
Model:
HSU-09H03/(BP)1
HSU-12H03/(BP)1Domestic Air Conditioner