EasyManua.ls Logo

Haier HSU-09HEA103 User Manual

Haier HSU-09HEA103
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
F
A
C
E
D
Drawing for the installation of indoor and outdoor units
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable
forindoorandoutdoor
Drain hose
Heating insulating material
Piping hole cover
Floor xing dimensions of the
outdoor unit (Unit:mm)
Fixing of outdoor unit
Fix the unit to concrete or blockƽ
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
ƽ
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
ƽ
house, fix the unit by attaching a
vibration-proof mat.
The marks from to
in the figure are the
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
ThemodelsadoptHFCfreerefrigerantR410A
more than
10cm
more than 5cm
more than 10cm
more than 10cm
more than
10cm
more than15cm
more than
60cm
A
G
ƽ
ƽ
Necessary Tools for Installation
Driverƽ
Torque wrench
ƽ
(17mm,22mm,26mm)
Nipperƽ
Reamerƽ
Hacksawƽ Pipe cutterƽ
Gas leakage detector orƽ
soap-and-water solution
Hole core drillƽ Flaring toolƽ
Spanner(17,19 and 26mm)ƽ Knifeƽ
Measuring tapeƽ
Indoor Unit
Place,robustnotcausingvibration,wherethebodycanbesupportedsufciently.ƽ
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
ƽ
Place,possibletodraineasily,wherepipingcanbeconnectedwiththeoutdoorunit.ƽ
Place,wherecoldaircanbespreadin a roomentirely.ƽ
Place, nearby a power receptacle, with enough space around. (Refer to drawings).ƽ
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
ƽ
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent
ƽ
lamps in the room are lightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.ƽ
Place, possible to bear the unit, where vibration and noise are not increased.ƽ
Place, where discharged wind and noise do not cause a nuisance to the neighbors.ƽ
Place, where a distance markedƽ
isavailableasillustratedintheabovegure.
Before inserting power plug into receptacle, check the voltage without fail.
The power
sourceisthesameasthe
ƽ
correspondingnameplate.
Install an exclusive branch circuit of the power.
ƽ
Areceptacleshallbesetupin a distancewherethepowercablecanbe
reached.
Donotextendthecablebycuttingit.
ƽ
Selection of Installation Place
Power Source
A
F
C
E
D
G
B
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
G
Preparation
Please be subject to the actual product purchased , the above picture is just for your reference.
Attention must be paid to
the rising up of drain hose
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual
NO.0010531113
Installation Manual of Room Air Conditioner
Question and Answer IconNeed help?

Do you have a question about the Haier HSU-09HEA103 and is the answer not in the manual?

Haier HSU-09HEA103 Specifications

General IconGeneral
BrandHaier
ModelHSU-09HEA103
CategoryAir Conditioner
LanguageEnglish

Summary

Installation Manual of Room Air Conditioner

Preparation

Outlines the initial steps and considerations before installation.

Necessary Tools for Installation

Lists essential tools required for the installation process.

Power Source

Details electrical requirements and safety precautions for the power supply.

Selection of Installation Place

Guides on choosing optimal locations for indoor and outdoor units.

Drawing for the installation of indoor and outdoor units

Illustrates the recommended placement and clearances for units.

Fixing of outdoor unit

Instructions on securely mounting the outdoor unit to a stable surface.

Accessory parts

Selection of pipe

Specifies the types and dimensions of pipes required for refrigerant lines.

Fitting of the Mounting Plate and Positioning of the wall Hole

Details on how to fix the mounting plate and mark the wall hole location.

Fixing the indoor unit body

Instructions for securely attaching the indoor unit to the mounting plate.

Connecting the indoor/outdoor Electric Cable

Steps for wiring the indoor and outdoor units, including cable management.

Outdoor unit

Installation of Outdoor Unit

Guidance on installing the outdoor unit according to diagrams and specifications.

Connection of pipes

Instructions for connecting the refrigerant pipes, including bending and torque.

Connection

Details on connecting electrical cables between indoor and outdoor units.

Purging Method: To use vacuum pump

Procedure for using a vacuum pump to purge refrigerant lines.

Refrigerant charge label

No gas leakage?

Steps to check for and address gas leaks after installation.

On Drainage

Instructions for correctly installing the drain hose to ensure proper water removal.

Power Source Installation

Ensuring the correct and safe installation of the power source.

Cutting and Flaring Work of Piping

Techniques for cutting and flaring refrigerant pipes for secure connections.

Check for Installation and Test Run

A checklist of items to verify during the final installation and test run.

Related product manuals