Frequency control form for wind volume 
  Limited frequency 
variables 
Limited frequency 
Medium wind volume 
FQLIMMD   
Weak wind volume  FQLIMLO   
When judging the conditions for frequency limit under the heating mode, first 
judge if the unit has been set to weak wind volume mode. If it has been set to one 
mode, then follow the table below for the limit modification. 
Outdoor temperature 
condition  
Indicated frequency  
011 (Below 20
℃
) Limited frequency for weak 
 
010(15-20
℃
) Limited frequency for weak 
 
001(10-15
℃
) Limited frequency for weak 
 
000(below10
℃
) Normal frequency  
 
3. Indoor blower fan control 
3-0-1. Targeted running speed 
 Model 09 
    Running speed variable
running speed
(rpm) 
Slightly weak  FRPMTBL00   
SSLO silent SSLO
FRPMTBL01   
Weak  FRPMTBL02   
Strong  FRPMTBL05   
Weak  FRPMTBL04   
 
 
 
Aut
oma
tic 
Strong  FRPMTBL05   
Slightly weak  FRPMTBL06   
SSLO silentSSLO 
FRPMTBL07   
 Weak  FRPMTBL08   
  Strong  FRPMTBL11   
Weak  FRPMTBL10   
 
Cooling 
 
Aut
oma
tic 
Strong  FRPMTBL11   
Weak  FRPMTBL12    
n   
Strong  FRPMTBL13   
Cooling  FRPMTBL09    
Quota 
Heating  FRPMTBL03   
. When the wind volume is manually  medium, the running speed is 
(strong+weak)/2. 
When it is automatically medium, the running speed is (strong automatic+ weak 
automatic)/2(not counted if it is not up to 10rpm) 
27
 