Overheat
protection for
exhaust
temperature
* 1The system is lack of
air or overloaded
with air
2The voltage is too
high (over 242V)or
too low (below
187V)
3The capillary tubes
may be blocked.
4Check if the sensor or
the controlling base
plate parts are wrong
5The indoor&outdoor
temperature could be
too high
AC electricity
protection
* 1 Check if the system
is overloaded with
air
2 Check if the voltage
is too low(below
187V)
3 Check if the CT or
the base plate parts
are all right
DC electricity
protection
* 1 Check if there are
seizes in the
compressor
2 Check if there are
damages of the
power modules
3 The voltage is too
high (over 242V)or
too low (187V)
Low power
protection
* 1Check if the voltage
is too low
2Check if the base
plate is damaged.
Outdoor base
plate temperature
temperature
* 1Check if the base
plate is all right
2The outdoor
environment
temperature could be
too high
Model:
HSU-12HS03/R2(DB)
HSU-09HS03/R2(DB)Domestic Air Conditioner
46

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HSU-09HS03/R2DB and is the answer not in the manual?

Haier HSU-09HS03/R2DB Specifications

General IconGeneral
BrandHaier
ModelHSU-09HS03/R2DB
CategoryAir Conditioner
LanguageEnglish

Related product manuals