compressor control:The compressor can’t be controlled by temperature sensor within 2 minutes after   
startup and can be only restarted at least 3 minutes later after shutdown. There is no 3-minute 
protection with power on for the first time (over 3 minutes with power off). The compressor 
must  
stands by for 3 minutes before it is restarted after shutdown. 
There is no 2-minute limit when changing the temperature setting or shutting down the machine   
through the remote controller, and the machine can be shut down immediately. 
Avoiding electrical shock: outdoor fan motor is available 2 seconds later after the compressor startup. 
Controlling the position of air door: set the position of air door as required. 
Protection of expiration of current peak value is available: Current cross detection is available in order   
to avoid burning out the compressor when the current is too big. The action character as 
follows:  
The compressor can’t be detected in 60 seconds after startup. when current is above “CT 1.6 V”   
and lasts 3 seconds, the system enter protection mode and shut off compressor with outdoor air   
blower and indoor fan motor controlled as the temperature sensor is off. After 3 minutes the   
machine can be started again. 
Protection of frost is available (disable in test run or heating mode): In order to prevent the indoor heat   
exchanger from freezing (in refrigation or dehumidifying mode), the compressor will be shut 
off   when the temperature of the indoor coil pipe is or below 0℃ and the  compressor runs 
for  over 5 minutes. When the temperature of the indoor coil pipe ascends to over 7℃, the 
compressor is restarted (must meet a 3-minutes delay) 
Timer on, Timer off and sleep control are available. 
2.3 Dehumidifying mode: (Tr: inlet air temperature,Ts:the set temperature) 
The background lighting of the LCD is aquamarine blue 
Temperature control range : 16℃—30℃ 
Temperature control precision: ±1℃ 
control character: 
  When Tr (indoor temperature) > Ts (temperature setting) +2℃, compressor and outdoor fan 
motor run continuosly with indoor fan motor runnig in accordance with the wind speed setting. 
  When Tr ranges from Ts to Ts +2℃, outdoor fan motor and compressor are on for 10 minutes 
and off for 6 minutes, the indoor fan motor is off in 3 minutes after shutdown of compressor 
and gives breeze in other time. 
  When Tr < Ts, outdoor fan motor and compressor are unavailable, and the indoor fan motor 
enter breeze mode 3 minutes later after shut down of compressor. 
  When all the ranges alternate, there is  ±1℃ difference.  
Wind speed control: 
    Automation: When Tr >= Ts + 5℃, the wind speed is high. 
              When Ts+3℃≤ Tr <Ts+5℃, the wind speed is medium. 
                    When Ts+2℃≤ Tr <Ts+3℃, the wind speed is low. 
                    When Ts≤ Tr <Ts+2℃, the machine gives breeze intermittently. 
When Tr < Ts, the indoor fan motor is shut off. in 3 minutes 
When Tr < Ts, the machine gives breeze after 3 minutes 
Manual operation: When the temperation sensor is off or the Indoor fan motor runs intermittently, 
the indoor fan motor can not be operated by hand (compelling automatic operation), along with 
Air Conditioner