Rated Heating
a Entry Condition: The unit will enter rated heating upon receipt of remote control
signal.
b Indoor unit will operate as per the following procedures when entering rated
heating mode:
Air fan will enter manual high wind (or rated wind) operation, panel will display
heating and rated data signal is in communication.
c Exit Conditions: The unit will exit rated operation when receiving remote control or
press-key signal and it will enter the mode set by remote control and press key.
3. Emergency Switch:
When unit is in shutdown condition, press emergency switch down for less than 5s,
the unit will start emergency operation.
When unit is in shutdown condition, press emergency switch down for more than 5s
but less than 10s, the unit will start trial operation.
When shutdown, press emergency switch down for more than 10s but less than 15s,
it will display the previous fault.
When unit is in shutdown condition, press emergency switch down, the panel will
display automatic operation.
When fault occurs, press emergency switch and the unit will shut down and fault is
cleared.
During fault display, press emergency switch will end fault display mode.