10
If central controller is connected and central control function is activated, the icon will display
on the wired controller. As a result, only on/o key of wired controller is available and other keys are
invalid.
If central controller is connected and central controller locked the wired controller, the icon
will
display on the wired controller. As a result, all keys of the wired controller are invalid.
Control / Lock function
When the wired controller is o , in cooling mode, hold for 10s to turn it on and activate forced
cooling function with ‘LL’ blinking in temperature display area. displaying cooling mode, setpoint
temperature 16°C and high fan speed. After forced cooling function is activated, only
is available
while other keys are invalid. Press
to exit forced cooling function and turn o the wired controller.
Forced cooling/ heating function
Operation
When the wired controller is o , in heating mode, hold for 10s to turn it on and activate forced
heating function with ‘HH’ blinking in temperature display area, displaying heating mode, setpoint
temperature 30°C and high fan speed. After forced heating function is activated, only
is available
while other keys are invalid. Press
to exit forced heating function and turn o the wired controller.
When the wired controller is turned on and select heating mode, high fan speed and adjust setpoint
temperature to 30°C (Maximum setpoint temperature when ECO function is activated), press
6
times in a row within 5s to set forced defrost function. The buzzer sounds 3 times indicates forced
defrost function is set successfully.
Forced defrost