Tostoreyour air conditioner, remove the unit from thewindow as per
the installation guide. Repackthe unit in its original box and store.
if you do not intend to remove it from the window then cover the
outside with a winter cover.
Thiscan be purchased from the retaibr where you purchased your
air conditioner or from your local hardware store.
Before putting away your unit make sure any water left in the pan is
removed and drained away. Water left in the pan could lead to rusting
or damage to the ebctrical connections.
if air conditioner does not operate:
* Check if unit is plugged in. The pJugmay have come loose.
* Check if the unit is inthe"Off" mode.
Thefan control may be in the"Off" position,
Air from air conditioner is warm:
* The A/C setting may need to be raised.
Thetemperature outside the room is beJow65°F. Thecompressorwill
not cyde on if the temperature outside is below 65°F.
ice formation on cooling coils:
* The outside temperature too cold. Settheunit on "fan only"
settingto defrost ice.
, Lower temperature setting. The temperature settingmay be too cold.
Theunit BTUmay be too high for the room.
15