EasyManua.ls Logo

Haier HWF05XCR - User Manual

Haier HWF05XCR
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
This Use & Care Guide is to be only used
for the mechanical control 5,000 BTU
models. Some mechanical 5,000 BTU
models may have an additional letter
after the model number.
NO.0010559927
Ce guide d’utilisation et d’entretien
nedoit être utilisé qu’avec les modèles
de 5,000 BTU à commande mécanique.
Sur certains modèles mécaniques
5,000BTU, le numéro de modèle
peutêtre suivi d'une lettre.
Esta Guía de uso y cuidado se debe usar
únicamente para los modelos 5,000 BTU
de control mecánico. Algunos modelos
mecánicos 5,000 BTU pueden tener
unaletra adicional después del número
de modelo.
HWF05XCR
User & Care Guide
Guide d'utilisation et d'entretien
Guía de uso y cuidado
Room Air Conditioner
Climatiseur individuel
Aire acondicionado
de uso doméstico
FAN ONLY
MIN
COOL
MAX
COOL
10
1
2
3
4
5
6
7
8
9
LOWHI
ON OFF
Wait 3 Minutes
Before Restarting
SPEED
POWER
Design may vary by model number. La configuration peut varier selon le
numéro de modèle.
El diseño puede variar conforme al
número de modelo

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Haier HWF05XCR and is the answer not in the manual?

Overview

This document is a User & Care Guide for a Haier Room Air Conditioner, specifically for mechanical control 5,000 BTU models (HWF05XCR). It provides comprehensive information on installation, operation, maintenance, and troubleshooting.

Function Description:

The Haier Room Air Conditioner is designed to cool a room by circulating air, removing heat, and maintaining a desired temperature. It operates as a window-mounted unit and is intended for residential use. The air conditioner features mechanical controls for adjusting temperature and fan speed.

Important Technical Specifications:

  • Model Number: HWF05XCR
  • Cooling Capacity: 5,000 BTU
  • Control Type: Mechanical
  • Electrical Requirements:
    • 115-Volt (103.5 min. to 126.5 max.)
    • 15-Amp time-delay grounded fuse or circuit breaker
    • Use on single outlet circuit only.
  • Power Supply Cord: Equipped with a 3-prong grounding plug and a Leakage Current Detection Interrupter (LCDI) device with TEST and RESET buttons.
  • Refrigerant: R410a (requires certified technicians for handling and disposal).
  • Window Opening Measurements (HWF05XCR):
    • Width Min/Max: 21 7/8" - 36" (556 - 914 mm)
    • Height Min: 13 3/8" (340 mm)

Usage Features:

  • Thermostat Control Knob: Allows users to set the desired room temperature. The knob typically ranges from MIN COOL to MAX COOL, with intermediate settings (1-10) and a FAN ONLY option.
  • Fan Speed Switch: Provides two fan speed options: HI (High) and LOW.
  • Power Switch: Turns the air conditioner ON or OFF.
  • Cooling Modes:
    • NORMAL COOL: Achieved by setting the SPEED switch to LOW and adjusting the thermostat control to the desired temperature.
    • MAX COOL: Achieved by setting the thermostat control to the MAX COOL mark.
    • FAN ONLY: For air circulation without cooling, set the thermostat control to FAN ONLY.
  • Air Directional Louvers: Adjustable louvers allow users to control the direction of airflow (left to right) to optimize cooling distribution in the room.
  • Safety Delay: An important operational feature is the 3-minute delay when turning the unit ON after it has been OFF, or when switching between cool mode and fan mode. This prevents compressor overload.
  • Temperature Operating Range: The air conditioner should not be operated when the outside temperature is below 61°F (16°C) to prevent the inside evaporator coil from freezing.

Maintenance Features:

  • Air Filter Cleaning: The air filter is removable for easy cleaning. It should be checked every two weeks during the operating season.
    • Cleaning Procedure: Turn off and unplug the unit, slide out the filter, clean with a vacuum cleaner (hose attachment) or wash with warm water and mild detergent if very dirty. Air-dry completely before reinserting.
    • Important Note: Do not wash the filter in a dishwasher or clothes washer, use chemical cleaners, or dry in a clothes dryer or microwave oven. Do not operate the unit without the filter installed.
  • Front Panel Cleaning: The front panel can be cleaned with a soft cloth after turning off and unplugging the unit. Avoid chemical cleaners, spray cleaners, sharp instruments, or flammable fluids as they can damage the surface. Air-dry the panel completely before plugging the unit back in.
  • Power Supply Cord Test: The LCDI power supply cord has TEST and RESET buttons. Users are advised to test the device periodically by pressing TEST (which should trip the RESET button) and then RESET (which should latch). If the device fails to trip or reset, the air conditioner should not be used, and a qualified service technician should be contacted.
  • Storage: The guide recommends keeping the carton and packing material for future use when removing, storing, and reinstalling the air conditioner.

Installation Requirements:

  • Location: Requires a grounded electrical outlet within 6 ft. (183 cm) of the power supply cord exit. It must be installed in a double-hung window, not through-the-wall.
  • Airflow: Ensure free movement of air in the room and that outside cabinet louvers and air discharge are not obstructed.
  • Tools Needed: Phillips head screwdriver, scissors, level, tape measure, drill and 1/8" bit, pencil.
  • Parts Supplied: Top channel, foam seal, side brackets, window lock bracket, 3/8" self-tapping screws, 1" wood screws, side curtains, side curtain frames.
  • Grounding: The unit must be properly grounded using its 3-prong plug into a mating, grounded 3-prong outlet.
  • Avoid: Extension cords, plug adapters, surge protectors, or multi-outlet adapters.

Troubleshooting:

The manual includes a troubleshooting section to address common issues such as the unit not starting, insufficient cooling, excessive cooling, frequent cycling, water dripping, and ice formation on the coil, providing possible causes and remedies.

Warranty:

The product comes with a ONE YEAR LIMITED WARRANTY covering defects in workmanship or material for mechanical and electrical parts (including labor costs) for 12 months from the date of purchase. The sealed system and compressor are covered for 1 year. Proof of purchase (original sales receipt) is required for warranty service. The warranty does not cover damages from improper installation, shipping, misuse, abuse, accident, lack of proper care, or service by unauthorized personnel.