MRV 5-RC Service Manual
SYJS-03-2019REV.A
Edition: 2019-03

Questions and Answers

  • C
    Calvin HamiltonSep 16, 2025
    How to fix current detecting circuit abnormal of compressor module in Haier MRV 5-RC AS122MNERA?
    • M
      Matthew AlexanderSep 16, 2025
      If the current detecting circuit of the compressor module is abnormal in your Haier Heat Pump, replace the inverter control board with abnormal current detection loop.
  • M
    Mr. Lucas JacksonAug 25, 2025
    What to do if four-way valve reversing failure in Haier MRV 5-RC AS122MNERA Heat Pump?
    • N
      Nicholas HartmanAug 25, 2025
      In case of a four-way valve reversing failure in your Haier Heat Pump, the suggested solution is to have it correctly replaced by after-sales service on site and ensure the refrigerant is sufficient.
  • K
    Kelly RitterAug 25, 2025
    How to fix outdoor compressor discharging temperature (Td1, Td2) too high failure in Haier MRV 5-RC AS122MNERA?
    • B
      Brent SimmonsAug 26, 2025
      If the outdoor compressor discharging temperature (Td1, Td2) is too high in your Haier Heat Pump, the suggested solution is to have the discharging temperature sensor replaced by after-sales personnel on site.
  • A
    Alexis SullivanAug 27, 2025
    What to do for fan motor module hardware over current in Haier MRV 5-RC AS122MNERA?
    • R
      Ricardo MeltonAug 27, 2025
      If the fan motor module in your Haier Heat Pump experiences a hardware over current issue, the solution is to replace the fan motor.
  • J
    Jennifer WheelerSep 18, 2025
    What to do if radiator temp. sensor of compressor module is abnormal in Haier Heat Pump?
    • K
      Kyle GraySep 18, 2025
      If the radiator temperature sensor of the compressor module is abnormal in your Haier Heat Pump, replace the variable frequency board.
  • D
    Daniel VaughnSep 23, 2025
    How to resolve AT24C04 EEPROM communication failure in Haier MRV 5-RC AS122MNERA Heat Pump?
    • J
      Justin GordonSep 23, 2025
      To resolve AT24C04 EEPROM communication failure, AT24C04 EEPROM data check failure, or IM EEPROM data or communication failure in your Haier Heat Pump, replace EE.
  • J
    James WilliamsSep 8, 2025
    How to fix emergency stop function switch failure in Haier MRV 5-RC AS122MNERA?
    • H
      hallseanSep 8, 2025
      If the emergency stop function switch fails in your Haier Heat Pump, short circuit the CN18.
  • N
    Nicholas WilsonSep 9, 2025
    What to do if incorrect settings of quantity, address or capacity for outdoor unit in Haier Heat Pump?
    • W
      William GordonSep 10, 2025
      If there are incorrect settings of quantity, address, or capacity for the outdoor unit of your Haier Heat Pump, the suggested solution is to research and lock the outdoor unit.
  • S
    stonedavidSep 3, 2025
    What to do if discharging temperature sensor Td1 and Td2 failure in Haier Heat Pump?
    • A
      anthonybenitezSep 3, 2025
      If the discharging temperature sensors Td1 and Td2 fail in your Haier Heat Pump, the solution is to have them correctly replaced by after-sales personnel on site.
  • A
    Ann DawsonSep 1, 2025
    What to do if outdoor unit compressor discharging temperature (Td1, Td2) too low failure in Haier Heat Pump?
    • K
      Kenneth CurrySep 1, 2025
      If the outdoor unit compressor discharging temperature (Td1, Td2) is too low in your Haier Heat Pump, the suggested solution is to have the discharging temperature sensor replaced by after-sales personnel on site.

Summary

Part 1. Outdoor Unit

1.2. Products lineup

Outlines the different outdoor unit models available in the MRV 5-RC series.

2. Specification

Lists detailed technical specifications for various outdoor unit models.

5. Piping diagram

Illustrates the piping system for outdoor unit models.

6. Wiring diagram

Provides a detailed wiring diagram for the main board and outdoor units.

10. Installation

Provides essential safety guidelines for the installation process.

Part 2. One by one valve box

1. Specification

Lists specifications for VP1-112B, VP1-180B, and VP1-280B valve boxes.

4. Wiring diagram

Shows the wiring diagram for the one-by-one valve box PCB.

5. Installation

Illustrates the installation connections for valve boxes.

Part 3. One by four valve box

1. Specification

Lists specifications for the VP4-450B one-by-four valve box.

4. Wiring diagram

Shows the wiring diagram for the one-by-four valve box PCB.

5. Installation

Illustrates installation connections for the VP4-450B valve box.

Part 4. Outdoor Unit Functionality

1. Outdoor PCB photo and dip switch setting

Shows a photo of the outdoor PCB and explains dip switch settings.

5. Troubleshooting

Provides a troubleshooting guide for various failure codes.

6. Sensor resistance table

Lists sensor models, names, codes, and their resistance characteristics.

7. Smartlink

Introduces Smartlink technology and its installation/debugging guidance.