Installation and Service Check List
Furnace Model: _______________________ Serial No.: ______________________
Installation Date: ______________________
Installer Name: ________________________ Phone No.: ______________________
Furn
Furnace level and in solid contact with floor?
ace Installation
□
□
Furnace and burner wired per wiring diagram and National Electric Code? 120VAC wiring Type_____ Size _____
AWG
□
Space is large enough to provide required clearances?
Burner sealed to furnace? Mounting nuts tight?
□
NFPA 31 Installation of Oil Burning Equipment followed? □
□
Local, state and national codes, laws, regulations and ordinances followed?
Ven
Existing chimney and vent system inspected to NFPA 211 and in good condition?
t System
□
New vent pipe installed and properly sealed? □
□
Vent size checked against furnace manual and codes?
Duc
Return and supply ducts checked for size based on furnace air flow and ACCA Manual D?
t Work
□
□
All ducts sealed and insulated as required?
Burn
Burner Model: __________________ Nozzle: _______GPH _______Deg. _______Type_______
er Operation
□
Burner Pump Pressure: ______________ □
Fuel filter and fuel lines installed and inspected as per burner manual? □
Air bled from oil piping? Piping checked for leaks? □
□
Burner started, adjusted and tested per burner manual?
Furn
Thermostat heat anticipator set per burner manual instructions?
ace Operation
□
Temperature rise through the furnace checked 75□
Blower motor amperage does not exceed rated full load amperage?
0
F maximum and blower speed adjusted as required?
□
Clean air filter installed? □
Limit control tested for proper operation? □
□
Furnace observed going through several operational cycles for proper operation?
Post
□ Reviewed owners’ information in this manual with owner or maintenance personnel and instructed to keep for future
reference?
Installation
□ Properly filled in and returned warranty registration card to Boyertown Furnace Co. Inserted burner manual
instructions with furnace manual for future use?