Instruction Manual
PU/PI and PS10
Differential Pressure
Transducers
halstrup-walcher GmbH
Stegener Straße 10
D-79199 Kirchzarten
Germany
Phone: +49 (0) 76 61/39 630
Fax: +49 (0) 76 61/39 6399
E-Mail: info@halstrup-walcher.com
Internet: www.halstrup-walcher.com
Document 7100.001784 Version 5.3 02/2010
Question and Answer IconNeed help?

Do you have a question about the halstrup-walcher PU10 and is the answer not in the manual?

halstrup-walcher PU10 Specifications

General IconGeneral
TypePressure Transducer
Process connectionG1/4" male
Operating temperature-10...+60 °C
Protection classIP65
Output signal4...20 mA
Supply voltage10 ... 30 V DC
Electrical connectionM12 connector
Process connection typeThread

Summary

Safety Precautions and Handling

1.1 Appropriate Use

Guidelines for proper usage and limitations of the differential pressure transducers.

1.2 Shipping, Assembly, Connections, and Start-up

Covers safe handling during shipping, assembly, electrical connections, and initial operation.

1.3 Troubleshooting, Maintenance, Repairs, and Disposal

Details procedures for error reporting, service, maintenance, and end-of-life disposal.

1.4 Symbols and Warnings

Explains symbols indicating potential hazards (bodily injury, property damage) and important information.

Instrument Description and Start-up

2 Instrument Description

Describes the PU/PI and PS10 transducers as pneumatic, electronic sensors for pressure measurements.

3 Start-up

Provides guidance on initiating the operation of the pressure transducers.

3.1 Features and Mounting

Highlights transducer robustness, precision, handling care, and optimal mounting recommendations.

3.2 Supply Voltage Connections

Illustrates terminal connections for AC and DC supply voltages to the instrument.

3.3 Analog Output Connections

Details terminal connections for various analog output signals (voltage and current).

Operation, Calibration, and Troubleshooting

4 Calibrating the Zero Point

Guides on calibrating the zero point after the transducer has warmed up, using the P0 trimmer.

5 Troubleshooting Guide

Provides common error descriptions, potential causes, and corrective actions for transducer issues.

Technical Data and Specifications

6 Technical Data

Lists comprehensive technical specifications including measurement ranges, overload, hysteresis, and ambient conditions.

Electrical Data

Details electrical specifications (power, voltage, load) and output signal options.

Physical Data

Covers pressure port size, electrical connections, mounting, dimensions, and protection class.

Appendix A: Materials

Lists materials used for parts that come into contact with the measurement medium.

7 Dimension Drawings

Presents detailed dimensional drawings for standard and LCD versions of the PU/PI/PS10 transducers.