EasyManua.ls Logo

Haltech ic-7 - DTM-4 Receptacle Pinout; 34-pin Superseal Connector Pinout; Platinum ECU Connection

Haltech ic-7
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
CAN Connection: DTM-4 receptacle
Pin Number Connection
1 +12V Supply
2 Battery Ground
3 CAN High
4 CAN Low
CAN Connection: 34 pin Superseal Connector
Pin Number Connection
1 CAN High
2 CAN Low
3 +12V Supply
4 Battery Ground
Rear View, Wire Side
Rear View, Wire Side
Connecting IC-7 Display Dash to a Haltech Platinum Series ECU:
You will need to use an 8-pin Tyco to DTM-4 cable to connect all Platinum Series ECUs to
this device. This cable is supplied with the ECU.
If you already have a Platinum Series ECU and are adding the IC-7 display dash to your
system this cable can be purchased separately (HT-130040).
ECU configuration for Elite Series ECUs
1. Connect to the ECU with the ESP software
(Elite Software Programmer)
2. Go into “Main Setup” (press F4)
3. Click “Devices” on the left tab
4. Under Haltech CAN System, enable the
Haltech CAN Supported Dash (see below)
5. For extended functionality of the IC-7 Display
Dash, Elite firmware 2.35 or later is required.
Earlier firmware versions are supported, but
some channels may not display.