EasyManua.ls Logo

Hamilton Engineering EVO HW 599 Series User Manual

Default Icon
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLING, OPERATING & MAINTAINING
EVO 299.2/.3–599.2/.3 High Eciency
Water Heaters and Heating Boilers
EVO 299.2/.3–599.2/.3
300,000 BTU/hr
399,000 BTU/hr
630,000 BTU/hr
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance
• Do not touch any electrical switch
• Do not use any phone in your building
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier instructions. If you cannot
reach your gas supplier, call the fire department.
If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or death.
WARNING
New York Massachusetts SCAQMD CEC Listed
MEA 425-05-E C1-0319-441 Compliant Rule1146.2 California Energy Commission
ANSI Z21.13-2014/CSA 4.9-2014
UL 795-2011/CSA 3.4
SCAQMD 1146.2
WARNING
These appliances MUST be installed by a properly licensed individual in
the City and State which the unit is being installed. All start up adjustments
and subsequent service work must be done by a similarly licensed
contractor or a factory trained service individual. Failure to comply could
result in loss of warranty and or severe personal injury, death and or
substantial property damage. These instructions are required to be
kept with the appliance on the left side, in the pocket provided.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hamilton Engineering EVO HW 599 Series and is the answer not in the manual?

Hamilton Engineering EVO HW 599 Series Specifications

General IconGeneral
CategoryWater Heater
SeriesEVO HW 599 Series
TypeTankless
Gas TypeNatural Gas or Propane
Water Connection Size3/4" NPT
Voltage120V
VentingDirect Vent
Maximum Water Temperature180°F
Activation Flow Rate0.5 GPM
BTU Input199, 000 BTU/hr

Summary

PART 2. ELECTRICAL

ELECTRICAL CONNECTION / REQUIREMENTS

Covers electrical connection standards, voltage, amperage, and grounding requirements for safe installation.

INTERNAL WIRING CONNECTION

Details field wiring connections, sensor inputs, and control board connections for proper functionality.

PART 3. GAS CONNECTION

GAS CONNECTION AND INSPECTION

Covers gas supply requirements, safety checks, leak testing, and approved gas types for installation.

GAS VALVE SETUP

Explains how to test gas pressure at different loads and ensure proper valve operation for optimal performance.

PART 4. VENTING

APPROVED VENTING MATERIALS

Lists approved materials and standards for vent pipes and fittings, including country-specific requirements.

VENTING THE EVO

Specifies vent diameters, types, minimum/maximum lengths, and equivalent feet for fittings.

PART 5. PIPING

HYDRONIC HEATING BOILER PIPING

Describes closed-loop system requirements, pressure, primary-secondary piping, and system components for boilers.

FILL & PURGE HEATING SYSTEM

Details the step-by-step process for filling and purging the heating system to remove air and sediment.

WATER HEATING PIPING

Outlines pipe sizes, pump specifications, and connection methods for water heating systems.

PART 6. START-UP PROCEDURES

ITEMS TO BE CHECKED BEFORE LIGHTING THE EVO

Lists critical checks before lighting the EVO, including reading the manual and verifying connections.

LIGHTING INSTRUCTIONS

Provides essential safety warnings and instructions for lighting the appliance, including gas leak procedures.

PART 7. SERVICING

EVO SOFT LOCKOUT CODES

Lists soft lockout codes for the CCB and BCB, their causes, and recommended actions for resolution.

EVO HARD LOCKOUT CODES

Lists hard lockout codes for the BCB, their causes, and recommended actions for resolution.

PART 8. MAINTENANCE

PART 9. SPECIAL INSTALLATION REQS

PART 10. PARTS BREAKDOWN