ENGLISH
20
Connection
The machine must be connected to the mains supply with a residual current device with a maximum
tripping current of 30 mA.
IMPORTANT: Only use clean water.
Use a suitable filter if there is a risk of sand getting into the inlet.
Safety devices
The machine is equipped with an overpressure valve.
The spray gun has a trigger lock.
The motor is equipped with overheating protection. The machine starts again after a few minutes,
when it has cooled.
Symbols
Read the Operating Instructions before use
Warning: Indicates a potentially dangerous situation.
Wear safety glasses.
Equipment, class II. Double insulation.
TECHNICAL DATA
Rated voltage
230 V ~ 50 Hz
Output
2200 W
Safety class
II
Protection rating
IPX5
Rated pressure
120 bar
Max. pressure
160 bar
Max. inlet pressure
7 bar
Rated flow
7.33 l/min
Rated temperature
040°C
Weight
21.1 kg
Sound pressure level, L
pA
77 dB(A), K=3 dB(A)
Measured sound power level, L
wA
84 dB(A), K=3 dB(A)
Guaranteed sound power level, L
wA
86 dB(A)
Vibration
2,5 m/s²
Always use hearing protection!