TROUBLESHOOTING
Buzzer/screen not activated during start
1� Make sure that the power supply is correctly connected to the connection box�
2� Make sure that the connection box has (+) 12V when reverse gear is engaged�
3� Check the earth connection�
4� Make sure that the equipment is correctly connected to the reversing light circuit�
5� Check that the screen is earthed and has the least (+) 12 V
False warning signal
1� Check whether the sensors are installed too low or directed towards the ground�
The sensors do not detect any objects
1� Check whether the vehicle's exhaust is very smoky� Rectify this fault before further testing�
2� Check that the sensors are connected correctly: