USER MANUAL For MULTISCAN P2
Chapter 4 - 18
b Automatic Trigger Mode (Triggered by DTC)
- MULTISCAN P2 will keep recording live data of selected parameters
up to 128 frames.
- Once a DTC is detected or the [ESC] key is pressed by the user, it
will proceed with recording remaining frames up to 2,040 or until you
abort.
- This function will let you have a set of data stream before and after
the ECM’s DTC recognition when you perform the test drive.
- Before DTC, you will see the Live Data of the selected parameters
keep refreshing, however, once triggered by DTC or [ESC] key
stroke, only the percentile process information and sampling
frequency will be displayed.