Do you have a question about the Hanna Instruments HI 718 and is the answer not in the manual?
Details common error and warning messages displayed by the instrument for troubleshooting.
Step-by-step guide for operating the HI 718 Iodine meter, including sample preparation and reading.
Provides essential advice to ensure precise and reliable measurements with the HI 718.
Covers battery life, indicators for low or dead batteries, and the procedure for battery replacement.
Lists available reagent sets and other accessories for the HI 718 Iodine meter.
Provides guidance on product suitability, interference correction, and instrument care.
Details common error and warning messages displayed by the instrument for troubleshooting.
Step-by-step guide for operating the HI 718 Iodine meter, including sample preparation and reading.
Provides essential advice to ensure precise and reliable measurements with the HI 718.
Covers battery life, indicators for low or dead batteries, and the procedure for battery replacement.
Lists available reagent sets and other accessories for the HI 718 Iodine meter.
Provides guidance on product suitability, interference correction, and instrument care.
This document describes the Hanna HI 718 Iodine Checker, a portable device designed for measuring iodine concentration in water.
The HI 718 Iodine Checker is a compact, handheld colorimeter that measures iodine levels in the range of 0.0 to 12.5 ppm (parts per million). It operates based on the DPD method, an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition. In this method, the reaction between iodine and a specific reagent causes a pink tint in the sample. The intensity of this pink color is then measured by the device to determine the iodine concentration.
The device features a Liquid Crystal Display (LCD) that shows measurement readings, error messages, and operational prompts. It has a single button for all operations, including turning the meter on, initiating measurements, and zeroing the device. The instrument includes a cuvette holder where sample cuvettes are placed for measurement.
The measurement procedure is straightforward:
The device provides several error and warning messages to guide the user:
Tips for accurate measurement include:
The HI 718 is designed with battery management features to extend battery life. It automatically shuts off after 2 minutes of non-use and 10 seconds after a reading is displayed. A fresh battery provides a minimum of 5000 measurements.
Battery Replacement:
The manual also recommends using specific accessories for maintenance and optimal performance:
Users are advised to ensure the products are suitable for their specific application and environment. They should avoid placing the instrument in a microwave oven and refrain from using or storing it in hazardous environments. Hanna Instruments reserves the right to modify the design, construction, and appearance of its products without advance notice.
| Brand | Hanna Instruments |
|---|---|
| Model | HI 718 |
| Category | Measuring Instruments |
| Language | English |












Loading...