WARRANTY
All Hanna Instruments meters are warranted for two years against defects in workmanship and
materials when used for their intended purpose and maintained according to instructions.
Probes are warranted for a period of six months.
This warranty is limited to repair or replacement free of charge.
Damage due to accidents, misuse, tampering or lack of prescribed maintenance are not covered.
If service is required, contact the dealer from whom you purchased the instrument. If under warranty,
report the model number, date of purchase, serial number and the nature of the problem. If the repair is
not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be
returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer
Service department and then send it with shipment costs prepaid.
When shipping any instrument, make sure it is properly packaged for complete protection.
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the
copyright owner.
Dear Customer,
Thank you for choosing a Hanna product.
This manual will provide you with the necessary information for the correct operation of
the meter. Please read it carefully before using the meter.
If you need additional technical information, do not hesitate to e-mail us at
tech@hannainst.com.
These instruments are in compliance with the directives.
Remove the instrument from the packing material and examine it carefully to make sure
that no damage has occurred during shipment. If there is any damage, notify your
Dealer.
Both models come supplied with:
HI 70602 RH/temperature probe
• 9V battery
• instruction manual.
Note: Save all packing material until the instrument has been observed to function
correctly. Any defective item must be returned in its original packing.
PRELIMINARY EXAMINATION
GENERAL DESCRIPTION
FUNCTIONAL DESCRIPTION
SPECIFICATIONS
Hanna Instruments reserves the right to modify the design, construction and appearance of its products
without advance notice.
Instruction Manual
HI 9564 - HI 9565
Portable
Water-Resistant
Thermo-Hygrometers
HI 9564 and HI 9565 are portable thermo-hygrometers for measurements of Temperature
and Relative Humidity. HI 9565 also shows the dewpoint calculated from the measured
Temperature and Relative Humidity.
The instruments are housed in a rugged, water-resistant casing for maximum protection
against effect of humidity and condensation.
The RH/temperature probe is a “smart probe” which contains the sensors, electronic sensor
drive circuitry and memory to store the calibration information. This allows interchange-
ability between probes and meters without recalibration.
Note: The RH probe sensor must never come into contact with water or other liquids.
Range
dewpoint (HI 9565 only)
Resolution
dewpoint (HI 9565 only)
Accuracy
dewpoint (HI 9565 only)
Typical EMC Dev.
dewpoint (HI 9565 only)
Probe (included)
Battery Type
Battery Life
Auto-off
Environment
Dimensions
Weight
20.0 to 95.0 % RH
0.0 to 60.0°C / 32.0 to 140.0°F (*)
-20.0 to 60.0°C / -4.0 to 140.0°F
0.1 % RH / 0.1°C / 0.1°F
0.1°C / 0.1°F
±3 % RH (50 to 85 % RH & 15 to 40°C); ±5% RH (outside)
±0.5°C / ±1°F
±2°C /±4°F (50 to 85 % RH & 15 to 40°C); ±4.5°C /±9°F (outside)
±1 % RH
±0.5°C / ±1°F
±0.5°C / ±1°F
HI 70602 RH/temperature probe
1 x 9V alkaline (IEC 6LR61)
250 hours of continuous use
after 20 minutes of non use
0 to 60°C (32 to 122°F); 98% RH non-condensing
164 x 76 x 45 mm (6.5 x 3.0 x 1.8")
340 g (12 oz.)
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used.
Operation of these instruments in residential area could cause unacceptable interferences to radio and TV
equipment, requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance.
To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24VAC or
60 VDC. To avoid damages or burns, do not perform any measurement in microwave ovens.
(*)Note: The meter measures temperature from -30 to 80°C, but the RH measurement can only be
taken within the range 0 to 60 °C.
www.hannainst.com
Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI 9564 and is the answer not in the manual?

Hanna Instruments HI 9564 Specifications

General IconGeneral
pH Range-2.00 to 16.00 pH
pH Resolution0.01 pH
pH Accuracy±0.01 pH
ORP Range±2000 mV
ORP Resolution1 mV
ORP Accuracy±1 mV
DisplayLCD
TypePortable Meter
Temperature Range-5.0 to 105.0°C
Temperature Resolution0.1°C
Temperature Accuracy±0.5 °C
CalibrationpH: automatic, up to five points with seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Power Supply4 x 1.5V AA batteries
pH Calibration Buffers1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45
Temperature CompensationAutomatic or manual from -5.0 to 105.0°C
PC ConnectivityYes, via USB
Environment0 to 50°C
Measurement RangepH: -2.00 to 16.00, ORP: -2000 to +2000 mV
ResolutionpH: 0.01, ORP: 1 mV
AccuracypH: ±0.01; ORP: ±1 mV

Summary

Functional Description

Liquid Crystal Display Overview

Explains the Liquid Crystal Display used for readings and status information.

Backlighting and Measurement Controls

Describes controls for backlighting, selecting measurements, and freezing readings.

Calibration and Data Management Controls

Details buttons for entering calibration mode and managing MIN/MAX data.

Preliminary Examination and Contents

Initial Inspection and Supplied Items

Instructs users to check for damage and lists items included with the meter.

Warranty and User Recommendations

Product Warranty Details

Outlines the two-year warranty for instruments and six-month for probes.

Important User Usage Guidelines

Provides essential recommendations for safe and effective use of the instruments.

General Description and Specifications

Instrument Functionality

Describes the HI 9564/9565 as portable thermo-hygrometers with water-resistant casing.

Technical Specifications Summary

Lists key technical data including range, resolution, accuracy, and environmental conditions.

Operational Guide and Error Messages

Instrument Setup and Basic Operation

Details connecting the probe, powering on, and using the RANGE button.

Measurement Freezing and Resetting

Explains how to freeze readings with HOLD and clear MIN/MAX data with CLEAR.

Backlighting and Power Off

Describes activating backlighting and turning off the instrument.

Slide Switch Functions

Explains how to select units, auto-off, and acoustic signal via slide switches.

Error Message Interpretation

Details common error messages and their meanings for troubleshooting.

RH Calibration and Battery Replacement

Relative Humidity Calibration Procedure

Guides users through the single-point offset calibration process for RH.

Battery Replacement Guide

Explains how to replace the battery and interpret low battery indicators.

Related product manuals