DG3 Controller – Installation and Operation
Manual
540846-3 page 27 of 64 25/09/2015
The following table shows all functions available in the status options:
DERIC-G3: controller model
V1.12: controller model software version number
Ok: indicates database loaded successfully
(otherwise, error code shown)
Name: name set in profile of controller config in Helen
(optional)
4 4 4 4 4 4 4 .: status of individual signs
1
- -: 2 external voltage signal inputs (# = active; - =
inactive)
9516( ): database file size in bytes (value in brackets
no longer used)
8.0Mb: flash memory capacity (needs to accommodate
both download file and operational database file)
RTC: Real Time Clock (available)
07C809: database file checksum value
00-02:45: timer / clock showing length of time in use
since last reboot (DD-HH:MM = days-hours:minutes)
25\04\2014: date (is displayed only if RTC is fitted and
enabled)
01:13: time (is displayed only if RTC is fitted and
enabled)
PF: controller profile
2
PF=X: where X indicates the value of the profile
Name: name set in profile of controller config in Helen
(optional)
This code monitors the status fed back from up to 8 passenger information signs that can be connected to the
RS485 port. Each digit corresponds to one sign. The possible values and their meanings are:
Sign connected and working correctly
Halogen bulb failure (applies to flip dot signs only but not to LED type signs)
This is a feature that makes it easy to manage a fleet of vehicles fitted with many different signs but all using the
same destination list. Full details are given in section 7.8.3 of the Helen v3.3 display-editing software - operating
manual (ref. 540125).
DERIC-G3 V1.12 Ok
Name
4 4 4 4 4 4 4 . - -
-
9516( ) 8.0Mb RTC
07C809 00-02:45
25\04\2014 01:13