Thermostatic Adjustment
Temperature Limitation
The temperature is limited by the safety stop to 40°C. If a higher temperature is
required, it is possible to over ride the safety stop by depressing the safety button.
NB. It is recommended that for private domestic use the maximum mixed water tem-
perature be set at the following factory set values:
Shower Mixer 43°C
Bath/Shower 43°C
Temperatures can be set by following the procedures on page 34. This ensures that
after correct installation the outlet temperature of the water can never exceed 43°C.
To guarantee a smooth running of the thermostatic element, it is necessary from time
to time to turn the thermostat from total hot to total cold. The thermostatic mixer valve
should be checked annually by a qualified person to ensure correct operation.
The mixer is fitted with check valves (page 38 pos. 95773000) and filters (page 38
pos 95773000 and 98282000). If the water flow drops the filters need to be cleaned.
For that purpose please follow the steps 1 - 9 on page 35.
Calibrating Thermostat
If the temperature reading is different to the showering temperature, follow the steps
1 - 5 on page 33.