Gloves should be worn during installation to prevent
crushing and cutting injuries.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 70°C
Recommended hot water temp.: 65°C
Thermal disinfection: max. 70°C ⁄ 4 min
The product is exclusively designed for drinking water!
Symbol description
Dimensions (see page 17)
Installation example (see page 18)
Finish set (see page 22)
Spare parts (see page 23)
Italiano
Montaggio
(vedi pagg. 20)
Indicazioni sulla sicurezza
Durante il montaggio, per pevitare ferite da
schiacciamento e da taglio bisogna indossare guanti
protettivi.
Istruzioni per il montaggio
• Prima del montaggio è necessario controllare che
non ci siano stati danni durante il trasporto. Una
volta eseguito il montaggio, non verranno riconosciu-
ti eventuali danni di trasporto o delle superfici.
• Montare, lavare e controllare tubature e rubinetteria
rispettando le norme correnti.
• Vanno rispettate le direttive di installazione nazionali
vigenti nel rispettivo paese.
Dati tecnici
Pressione d'uso: max. 1 MPa
Pressione d'uso consigliata: 0,1 - 0,5 MPa
Pressione di prova: 1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Temperatura dell'acqua calda: max. 70°C
Temp. dell'acqua calda consigliata: 65°C
Disinfezione termica: max. 70°C ⁄ 4 min
Il prodotto è concepito esclusivamente per acqua
potabile!