Hurricane-AW
Manual v1.1
2021
Distributed by :
Hansol Global Corporation
#43-4 Sicheongro , 677beongil Paltan-myeon Hwasung-si Gyeonggi-do S.
Korea
www.colorfirefly.com
diotima1201@gmail.com
0Hurricane-AW
Question and Answer IconNeed help?

Do you have a question about the Hansol Hurricane-AW and is the answer not in the manual?

Hansol Hurricane-AW Specifications

General IconGeneral
BrandHansol
ModelHurricane-AW
CategoryCamera Accessories
LanguageEnglish

Summary

General Safety Information

General Description and Components

Introduction

Hurricane-AW is a moving flame system with a 180° swiveling head, providing up to 7m flame. It's an all-in-one device.

Features

Lists key features like all-in-one design, built-in pumps, accumulator, motorized head, and electric spark ignition.

Package Detail

Lists the items included in the package: 1 Hurricane-AW device, power cord, DMX cable, and user manual.

Operator Preparations

Requires fuel (Isopar, Isopropyl alcohol) and a DMX controller. Advises against specific fuel colors.

Technical Specifications

Hurricane-AW Overview

Control Panel Overview

DMX 512 Control

DMX Key Value

Explains DMX channels, spark ignition, solenoid valve, and pump operation ranges.

Setting DMX Starting Address

Details how to set the starting DMX address using the control panel buttons and screen.

Handling Hurricane AW

Audience-Side Definition

Defines the audience-side of the device and how sequences and positions are viewed from this perspective.

Position Definitions

Explains the 9 positions of the 180° spectrum and their corresponding angles and DMX keys.

DMX Channels Overview

Detailed DMX Channel Functions

Channel 1: Angle

Controls the angle of the moving flame head based on DMX key values.

Channel 2: Flame - Solenoid Valve

Enables manual or programmed flame shooting when pump and ignition are active.

Channel 3: Electric Spark

Activates electric spark ignition with specific DMX values, requiring pump activation.

Channel 4: Pump

Manages the internal pumps, pressurizing fuel to 18bar and entering standby mode.

Channel 5: Stepp Sequence of Single Flame Shot

Accesses pre-made single flame shot sequences at various angles via DMX key values.

Bank and Transit Time Channels

Channels 6, 9, 12, 16, 18: Bank Channels

Selects pre-programmed autoshow sequences across different banks.

Channels 7, 10, 13, 16, 19: Loop Channels

Determines the number of times each autoshow sequence is looped.

Channels 8, 11, 14, 17: Transit Time Channels

Sets the transition time between different banks for autoshow sequences.

Autoshow Sequence List

Set Up Procedures

Safety Functions

Maintenance

Cleaning

Instructions for cleaning the device using wet towels, avoiding solvents and abrasives.

Leaking Test

Procedure for performing regular leaking tests every six months.

Filter Maintenance

Information on the built-in filter and how to clean it to maintain flame height.

High Voltage Warning

Caution regarding high voltages generated for electrical ignition and safety precautions.