BS03
Fixed gas detector
Operation manual
Read this manual carefully before using the device
Ver:HWWM160617CG

Questions and Answers

  • N
    Nathan HoganAug 2, 2025
    What to do if my Hanwei Other shows NO response to gas?
    • F
      fmyersAug 2, 2025
      If your Hanwei Other is not responding to gas, it could be due to sensor damage, in which case you should replace the sensor. Alternatively, there might be an electrical fault, and you should contact the seller.
  • A
    Andrew ForbesAug 7, 2025
    What does E-02 error mean on my Hanwei BS03 Other, and how to fix it?
    • E
      Emily VasquezAug 7, 2025
      The E-02 error on your Hanwei Other indicates a wiring fault, connection fault, or sensor fault. To resolve this, try reconnecting the wire or replacing the sensor.
  • Z
    Zachary DavisAug 12, 2025
    Why does my Hanwei BS03 display E-04 error?
    • P
      patriciabrownAug 12, 2025
      The E-04 error on your Hanwei Other is due to sensor drift. The suggested solution is to replace the sensor.
  • S
    stephaniesawyerAug 17, 2025
    What does E-01 error mean on my Hanwei Other, and how can I solve it?
    • L
      leslieparsonsAug 17, 2025
      The E-01 error on your Hanwei Other indicates a calibration fault. You should recalibrate the device.
  • T
    thompsonmichaelAug 22, 2025
    What does E-06 error mean on Hanwei Other, and how to fix it?
    • N
      Nicholas KennedyAug 22, 2025
      The E-06 error on your Hanwei Other indicates a fault with the system’s parameters. To fix this, reload the system parameters.
  • A
    Alexis StoneAug 27, 2025
    What to do if my Hanwei BS03 Other has abnormal connection with controller?
    • S
      Samantha NortonAug 27, 2025
      If your Hanwei Other has an abnormal connection with the controller, it could be due to a wiring fault. In that case, check the wiring. Alternatively, it might be an electrical fault, and you should contact the seller.

Summary

Safety Information

General Safety Precautions

Provides crucial safety instructions for operating the BS03 fixed gas detector, including handling, voltage, environment, and maintenance.

Brief Introduction

Main Technical Specifications

Device Structure

Installation

Installation Position

Details on selecting the optimal location for installing the gas detector based on gas properties and environmental factors.

Dimensions

Provides the physical dimensions of the BS03 fixed gas detector with a diagram.

Installation Methods

Describes various methods for physically mounting the BS03 fixed gas detector, including pipe and wall mounting.

Wire Connection

Operation

Low Alarm Setting

Procedure for configuring the low alarm threshold of the BS03 fixed gas detector using the remote controller.

High Alarm Setting

Procedure for configuring the high alarm threshold of the BS03 fixed gas detector using the remote controller.

Zero Translation

Explains zero drift and the process for zero translation to correct detector readings in clean air.

Single Point Calibration

Instructions for performing single-point calibration of the BS03 fixed gas detector using standard calibration gas.

Address Code Setting

Guide to setting the address code for RS485 output signal using internal dial switches.

Sensor Replacement

Troubleshooting Guidance

Hanwei BS03 Specifications

General IconGeneral
Sensor TypeSemiconductor
Response Time≤30 seconds
Alarm MethodVisual and Audible
Operating Temperature50°C
Operating Humidity≤95%RH (non-condensing)