Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com
63402
Owners Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference. 17j
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright
©
2016 by Harbor Freight Tools
®
. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and s er vi ce m ay n ot be i nc lu de d.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.

Questions and Answers

  • C
    Christina MillerAug 2, 2025
    What to do if my Harbor Freight Tools creekstone 63402 won't start?
    • J
      jessicashawAug 2, 2025
      If your Harbor Freight Tools Water Pump won't start, there are several potential causes: 1. A disconnected cord. Ensure the cord is plugged in. 2. Low water level. Move the pump to a location where it remains fully submerged. 3. A clogged filter, Inlet Screen, or impeller. Remove the Inlet Screen and clean these components, then reinstall the Inlet Screen. 4. A kinked or obstructed discharge hose. Straighten the hose and flush it with clear water. 5. A broken or jammed impeller. Open the pump and turn the impeller to ensure it spins freely. Keep the filter in place during use to prevent impeller damage. 6. Defective motor or power connections. Consult an electrician or a qualified service technician to repair or replace the defective parts.
  • L
    Lisa MaddoxAug 9, 2025
    Why is my Harbor Freight Tools Water Pump running but not pumping water?
    • C
      Carrie JarvisAug 9, 2025
      If your Harbor Freight Tools Water Pump runs but doesn't pump water, consider these possibilities: * The Inlet Screen or impeller may be clogged. Remove the Inlet Screen and clean any dirt or debris from it and the impeller, then replace the Inlet Screen. * The water level may be too low during startup. The pump must remain completely submerged at all times for proper operation after startup. * The check valve (sold separately) might be stuck or installed backward. Remove and examine the check valve. * There may be low line voltage. It is recommended to consult an electrician.
  • C
    Courtney CallahanAug 15, 2025
    How to reduce excessive noise from Harbor Freight Tools creekstone 63402 Water Pump?
    • D
      Destiny BennettAug 15, 2025
      Excessive noise or vibration in your Harbor Freight Tools Water Pump can be caused by: * Debris in the impeller. Remove the Inlet Screen, clean the impeller, and reinstall the Inlet Screen. * A restricted discharge hose. Clean the pump and discharge hose.
  • G
    Guy GomezAug 21, 2025
    Why does my Harbor Freight Tools creekstone 63402 Water Pump start and stop frequently?
    • J
      Jason BushAug 21, 2025
      If your Harbor Freight Tools Water Pump starts and stops frequently, it might be due to: 1. Water temperature being too high. Do not exceed 95° F (35°C). 2. A check valve (sold separately) being stuck or installed backward. Remove and examine the check valve. 3. Backflow of water from the discharge hose. Install or inspect the check valve (sold separately).
  • M
    marie46Aug 27, 2025
    What causes low flow in Harbor Freight Tools Water Pump?
    • L
      Leah HoffmanAug 27, 2025
      If your Harbor Freight Tools Water Pump has low flow, the impeller may be clogged. Check and clean it according to the instructions.

Summary

Owners Manual & Safety Instructions

Save This Manual

Keep this manual for safety warnings, assembly, operating, inspection, maintenance, and cleaning procedures for future reference.

Important Safety Information

Read this material before using the product to prevent serious injury. Save this manual.

Pre-Start Up and Safety Precautions

Electrical Requirements

Pump must be connected to a GFCI protected 120VAC, 60Hz outlet. Protect electrical connections from moisture.

General Operating Safety

Avoid risks of electric shock, flooding, caustic fluids, frost, running dry, and ensure child safety.

Drip Loop and Extension Cords

Arrange a "drip loop" in the cord. Do not use an extension cord with this pump.

Fluid Type Restrictions

Use only fresh water up to 95°F (35°C). Do not use for heated liquids, fuels, chemicals, salt, or chlorinated water.

Specifications and Installation

Product Specifications

Details electrical rating, cord length, maximum flow, maximum head lift, and discharge port for both models.

Installation Guidelines

Proper pump placement, submersion, distance from receptacle, and hose connection for optimal operation.

Power Supply and Area of Use

Connect to GFCI outlet, ensure cord condition, position with drip loop, and use only in fresh water areas.

Pump Operation

Before Starting the Pump

Verify pump placement, discharge pipe connection, electrical connection, GFCI outlet, and water coverage.

Maintenance and Troubleshooting

Quarterly Maintenance

Steps for unplugging, cleaning inlet screen, impeller, and hoses every three months.

Troubleshooting Guide

Solutions for common issues like no water, no start, low flow, noise, and frequent stopping.

Parts List and Diagram

Component Identification

Lists all parts with their corresponding numbers, descriptions, and quantities.

Assembly Diagram

Visual Component Breakdown

Illustrates the pump's components with numerical labels for identification.

Limited 90 Day Warranty

Warranty Coverage and Claims

Details the 90-day warranty, exclusions, and procedures for returning products for service.

Harbor Freight Tools creekstone 63402 Specifications

General IconGeneral
Model63402
Power SourceElectric
Voltage120V
Housing MaterialThermoplastic
Float SwitchYes
Outlet Size1-1/4 in
Hose Size1-1/4 in