ALPHA PLUS HARDI NOVA
MM AA II NN TT EE NN AA NN CC EE
CHAPTER
55-
8
55-
22
-
77
EEVVEERRYY
10
HHOOUURRSS
OR
DDAAIILLYY
SSpprraayy ffiilltteerrss
55-
22
-
66
EEVVEERRYY
HOURS
AAiirr ccoonnddiittiioonniinngg CCoonnddeennsseerr
- Clean the area around the filling cap.
- Fill hydraulic oil through a filter unit to guarantee the purity. Filter ratio : 10 micron
absolute or better.
For a good draining of the oil, it is preferable for the machine to have been running
prior to the hydraulic oil change
- Check the hydraulic oil level through the sight glass situated on the reservoir
An audible warning located on under the instrument panel indicates a lack of oil in
the hydraulic system. Check the hydraulic circuit immediately for leaking and refill oil
AA LL WW AA YY SS UU SS EE AA SS II MM II LL AA RR HH YY DD RR AA UU LL II CC OO II LL
hhyyddrraauulliicc ooiill lleevveell
- Remove the 4 screws
((11))
by using a hex. spanner (size 4mm) and
remove the access doors
((22))
.
- Blow out condenser device
((33))
with compressed air
- re-assemble the access doors
IItt iiss rreeccoommmmeennddeedd ttoo uussee eeyyee // ffaaccee pprrootteeccttiioonn mmaasskk wwhheennbblloowwiinngg oouutt tthhee
ccoonnddeennsseerr ddeevviiccee
11
33
22