CASSETTE
MECHANISM
ADJUSTMENT
AND
CONFIRMATION
1.
Pinch
roller
contact
timing
1)
Run
the
capstans
by
placing
the
POWER
switch
in
the
ON
position.
2)
Lift
the
head
base
slowly
until
the
take-up
pinch
roller
starts
rotating.
Then
confirm
that
there
is
a
clearance
of
0.05~ 0.5mm
between
the
supply
pinch
roller
and
the
capstan.
Capstan
Clearance
fy
0.05
~0.5
mm
5
LI}
Ae
@
6
&
OO
Supply
pinch
roller
Not
rotating
Take-up
pinch
roller
Rotating
Fig.
1
3)
If
the
pinch
roller
contact
timing
is
simultaneous
or
reverse,
advance
the
pinch
roller
contact
timing
of
the
take-up
pinch
roller
by
bending
the
A
section
in
the
below
Fig.
2
in
the
arrow
direction
or
replace
the
supply
pinch
roller
assembly.
Note:
{f
the
contact
timing
has
been
adjusted
by
bending
the
A
section
of
the
head
base,
be
sure
to
confirm
after
the
adjustment
that
the
capstan
and
the
take-up
pinch
roller
are
not
in
contact
while
the
deck
is
in
the
PAUSE
mode.
Head
base
Fig,
2
2.
Pinch
roller
parallelism
confirmation
1)
Push
up
the
head
base
until
right
before
the
capstan
and
pinch
roller
contact
and
visually
confirm
for
parallelism
of
each
capstan
and
the
pinch
roller.
Capstan
Parallelism
Pinch
roller
Fig.
3
2)
If
out
of
parallelism,
check
the
pinch
arm
spindle
for
bend
and
if
not
bent,
replace
the
pinch
roller
assembly.
3.
Specification
confirmation
Check
for
the
following
specifications.
1)
Back
tension
6
gem
(4.5
~
8gcm)
2)
Pinch
roller
pressure
Tape-up
360g
+
40g
Supply
260g
+
40g
4.
Head
height
adjustment
1)
Install
the
M-300
head
gauge
plate.
2)
With
the
unit
in
the
PLAY
state,
apply
the
adjustment
chip
to
the
head
gauge
plate
and
make
an
adjustment
with
the
adjusting
screws
A
and
B
in
the
below
Fig.
4
so
that
the
chip
doesn’t
contact
the
tape
guide.
‘M-300
Head
gauge
plate
Adjustment
chip
Tape
guide
Adjustment
B
Fig.
4
5.
Head
penetration
adjustment
1)
Install
the
M-300
head
gauge
plate.
2)
Apply
the
adjustment
chip
to
the
head
and
check
for
the
chip
to
head
clearance.
If
there
is
a
clearance,
make
an
adjustment
with
the
adjusting
screw
C
so
that
no
clearance
remains.
Note:
1.
There
should
be
no
clearance
at
either
record
or
playback
head.
2,
If
there
is
a
clearance
at
either
record
or
playback
head,
adjust
so
that
the
clearance
will
be
at
the
lower
side
as
shown
in
the
Fig.
5.
3.
After
the
flapping
adjustment,
re-check
the
head
height.
M-300
Head
gauge
plate
Head
Adjustment
chip
WiLL
‘Head
gauge
Clearance
_plate
c
Fig.
5
ahi