LEAKAGE
TEST
(FOR
SERVICE
ENGINEERS
IN
THE
U.S.A.)
Before
returning
the
unit
to
the
user,
perform
the
following
safety
checks:
1.
Inspect
all
lead
dress
to
make
cer-
SIMPSON
MODEL
229
ETC.
FOR
LEAKAGE
TEST
tain
that
leads
are
not
pinched
or
that
hardware
is
not
lodged
be-
TO
EACH
EXPOSED
TO
AC
GROUND
SUCH
tween
the
chassis
and
other
metal
METAL
SURFACE
OF
aii
Coe
el
eee
CABLE,
.
:
UNIT
UNDER
TEST
H
GROUND
,
parts
in
the
unit.
VOLTAGE
LEAD
2.
Replace
all
protective
devices
such
OR
+LEAD
as
nonmetallic
control
knobs,
in-
sulating
fishpapers,
cabinet
backs,
adjustment
and
compartment
cov-
ers
or
shields,
isolation
resistor-
capacitor
networks,
mechanical
in-
sulators,
etc.
3.
Be
sure
that
no
shock
hazard
exists;
check
for
leakage
current
using
Simpson
Model
229
Leakage
Tester,
standard
equipment
item
No.
21641,
RCA
Model
WT540A
or
use
alternate
method
as
follows:
Plug
the
AC
line
cord
directly
into
a
120-volt
AC
receptacle
(do
not
use
an
Isolation
Transformer
for
this
test).
Using
two
clip
leads,
connect
a
1500
ohm,
10-watt
resistor
paralleled
by
a
0.15
4F
capacitor,
in
series
with
all
exposed
metal
cabinet
parts
and
a
known
earth
ground,
such
as
a
water
pipe
or
conduit.
Use
a
VTVM
TO
EXPOSED
CONNECT
TO
KNOWN
or
VOM
with
1000
ohms
per
volt,
or
higher
sensitivity
to
measure
METAL
PARTS
EARTH
GROUND
the
AC
voltage
drop
across
the
resistor.
(See
Diagram.)
Move
the
resistor
connection
to
each
exposed
metal
part
having
a
return
path
to
the
chassis
(antenna,
metal,
cabinet,
screw
heads,
knobs
and
control
shafts,
escutcheon,
etc.)
and
measure
the
AC
voltage
drop
across
the
resistor.
(This
test
should
be
performed
with
the
power
switch
in
both
the
On
and
Off
positions.)
A
reading
of
0.35
volt
RMS
or
more
is
excessive
and
indicates
a
potential
shock
hazard
which
must
be
corrected
before
returning
the
unit
to
the
owner.
VTVM
OQ
AC
SCALEQ
TEST
PROBE
POWER
CORD
REPLACEMENT
(FOR
SERVICE
ENGINEERS
OTHER
THAN
NORTH
AMERICA)
In
order
to
prevent
file
or
shock
hazard
when
replacing
the
power
cord,
follow
the
procedure
below
to
replace
the
parts
with
the
standard
supply
parts.
PI
CABINET
BACK
POWER
CORD
Sy
HOLDER