The IR Setting window has the following controls:
Fault DetectionIf an IR code is sent but no IR emitter is connected, a fault will be registered
IRCarrierThis setting determines whether the IR carrier frequency (typically 41kHz) is present in the output
signal. This should always on for use with an IR emitter. Some wired IR connections may require removal of the
IR carrier frequency
Off TimeFor queued IR pulses such as Keypad Macros and IR Pulse this setting determines the time between
queued IR pulses
On TimeFor queued IR pulses such as Keypad Macros and IR Pulse this setting determines the total
transmission time for the IR pulse