Service and display messages
43
Service and display messages
The MAC Aura PXL gives service and maintenance information by displaying a large 3- or 4-character short
code and a smaller full-text message in the fixture’s display. The short code is visible at a distance, allowing
easier reading with the fixture still in the rig, for example, while the full-text message gives more detailed
information.
Warning messages
Warning messages indicate that either:
problems might appear in the future if no action is taken, or
the user needs to pay special attention to a function or procedure when working with the fixture.
The MAC Aura PXL communicates warnings as follows:
Warning codes are shown continuously in the display and disappear when the user reacts to the warning.
If more than one warning is detected, all warnings are displayed in sequence.
If the display is inactive, the fixture’s status LED (see Figure 2 on page 9) flashes orange to indicate that
there is a warning. Activating the display will show the warning.
The possible warning messages are listed in Table 7 below
:
*High temperature warnings are canceled as soon as temperature returns to normal. If temperature reaches
cutoff level, the warning is replaced by a cutoff error message.
Short code
Long message and explanation
BANK
BANK NO ACCESS
Error unpacking firmware bank during/after software upload. Fixture will continue to operate on
existing firmware. Warning message is cleared by a successful software upload or at the next
power off/on cycle.
DCTW
DC TEMP HIGH
DC PCB sensor detects abnormally high operating temperature.*
LDTW
LED DRV TMP HIGH
LED driver temperature sensor detects abnormally high operating temperature.*
PFTW
PFC TEMP HIGH
PFC unit temperature sensor detects abnormally high operating temperature.*
PTTW
PT TEMP HIGH
Pan/tilt PCB sensor detects abnormally high operating temperature.*
SERV
SERVICE MODE
Fixture in service mode.
SL W
SAFETY LOOP
A safety loop error occurred but is no longer active. Warning message is cleared at the next
power off/on cycle.
UITW
UI TEMP HIGH
User interface (LCD display and control panel) PCB sensor detects abnormally high operating
temperature.*
ZFTW
ZF TEMP HIGH
Zoom PCB sensor detects abnormally high operating temperature.*
Table 7: Warning messages