7P43 Pellet Stove3-90-04301R18_03/13
Installing 
Place the stove on a noncombustible type oor or oor protector 
that extends a minimum of 6 inches (152mm) to the front of the 
load door opening, 6 inches (152mm) to the sides of the door 
opening, and 6 inches to the rear. Floor protection must also 
extend 2 inches (51mm) beyond each side of any horizontal ue 
pipe. The  minimum oor  protector material  is 20 gauge sheet 
metal.  Other  oor  protector  materials  are ceramic  tile,  stone, 
brick, etc.
NOTE for Canadian installation only: Per ULC-S627-00, 
If installed on a combustible floor, the need to provide a 
noncombustible oor protector  covering the area beneath the 
space heater and extending at least 17.72" (450mm) on the ring 
side and at least 7.87" (200mm) on the other sides.
In  Canada,  you  may  follow  smaller  U.S.  oor  protection 
requirements ONLY if the user agrees to completely shut-
down the appliance, and allow it to cool to where all re is 
extinguished and the combustion blower and its indicator 
light shuts off, prior to opening the rebox door or ash door.
Place the stove away from combustible walls at least as far as 
shown in Figures 3 and 4. Please note the difference in side wall 
clearance with and without side shields. 
Note that the clearances shown are minimum for safety but 
do not leave much room for access when cleaning or servicing. 
Please take this into account when placing the stove. 
Connect the power cord to a 120 V.A.C. 60Hz grounded 
receptacle. (A surge protector is recommended to protect the 
circuit board.)  Also be sure that the polarity of the outlet that the 
stove is plugged into is correct.
Prior  to  installing  the  ue  pipe,  connect  a  draft  meter.  (The 
draft meter must have a minimum range of 0 - .5") Record the 
rst reading. Connect ue pipe to stove and be sure all doors 
and windows in the home are closed.  Record the second draft 
reading_______.  If the second reading is more than .05" lower 
than the rst reading, check for possible restrictions or the need 
for outside air (see page 10). For more information on the draft 
test procedure, refer to Page 21.
Mobile Home Installation
When installing this unit in a mobile home, several requirements 
must be followed: 
1. The unit must be bolted to the oor. This can be done with 1/4" 
lag screws through the 2 holes in the base plate.
2. The unit must also be connected to outside air. See page 10.
3. Floor protection and clearances must be followed as shown.
4. Unit must be grounded to the metal frame of the mobile home.
CAUTION: This appliance must be vented to the outside.
Due to high temperatures, the stove should be placed out of 
trafc and away from furniture and draperies.
Children and adults should be alerted to the hazards of high 
surface temperatures and should stay away  to avoid burns to 
skin and/or clothing.
Young children should be carefully supervised when they are in  
the same room as the stove.
Clothing and other ammable  materials should not  be placed 
on or near this unit.
Installation
Minimum Size  oor protection  (USA) is  32
1/2
" wide By 
33" deep (825mm X 838mm).
* Floor protection dimensions for the front and sides 
are measured from the appliance door opening in 
The United States. In Canada, the side dimension is 
measured from the widest part of the appliance.
NOTE: 
Measurement "L" 
is measured from 
the pedestal base 
in the US ONLY
NOTE: 
Measurement "K" 
is measured from 
the glass in the 
US ONLY
L
J
Floor Protection 
Requirements
US
Canada
Sides
Rear
6" 200mm
6" 200mm
K
Front
6" 450mm
THE STRUCTURAL INTEGRITY OF THE 
MANUFACTURED HOME FLOOR, WALL, AND 
CEILING/ROOF MUST BE MAINTAINED.
WARNING
DO NOT INSTALL IN SLEEPING ROOM.
Fig. 3
9"(228mm)With or W/Out Side Shields
9"(228mm)
9"(228mm) 
Alternate floor protector 
dimension may be used 
as long as they satisfy the 
measurement requirements 
shown below.
Minumum size oor protection 
for a corner installation hearth 
pad is 36" x 36". Clearance 
shown as 9" with optional side 
shields installed.
Fig. 4
2"(51mm)
36"(914mm)
10" (254mm) with 
side shields
16" (406mm) 
without side shields
10" (254mm)
16" (406mm)
J
USA
K
L
J
CANADA
Floor protector