7P43 Pellet Stove3-90-04301R18_03/13
Installing
Place the stove on a noncombustible type oor or oor protector
that extends a minimum of 6 inches (152mm) to the front of the
load door opening, 6 inches (152mm) to the sides of the door
opening, and 6 inches to the rear. Floor protection must also
extend 2 inches (51mm) beyond each side of any horizontal ue
pipe. The minimum oor protector material is 20 gauge sheet
metal. Other oor protector materials are ceramic tile, stone,
brick, etc.
NOTE for Canadian installation only: Per ULC-S627-00,
If installed on a combustible floor, the need to provide a
noncombustible oor protector covering the area beneath the
space heater and extending at least 17.72" (450mm) on the ring
side and at least 7.87" (200mm) on the other sides.
In Canada, you may follow smaller U.S. oor protection
requirements ONLY if the user agrees to completely shut-
down the appliance, and allow it to cool to where all re is
extinguished and the combustion blower and its indicator
light shuts off, prior to opening the rebox door or ash door.
Place the stove away from combustible walls at least as far as
shown in Figures 3 and 4. Please note the difference in side wall
clearance with and without side shields.
Note that the clearances shown are minimum for safety but
do not leave much room for access when cleaning or servicing.
Please take this into account when placing the stove.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommended to protect the
circuit board.) Also be sure that the polarity of the outlet that the
stove is plugged into is correct.
Prior to installing the ue pipe, connect a draft meter. (The
draft meter must have a minimum range of 0 - .5") Record the
rst reading. Connect ue pipe to stove and be sure all doors
and windows in the home are closed. Record the second draft
reading_______. If the second reading is more than .05" lower
than the rst reading, check for possible restrictions or the need
for outside air (see page 10). For more information on the draft
test procedure, refer to Page 21.
Mobile Home Installation
When installing this unit in a mobile home, several requirements
must be followed:
1. The unit must be bolted to the oor. This can be done with 1/4"
lag screws through the 2 holes in the base plate.
2. The unit must also be connected to outside air. See page 10.
3. Floor protection and clearances must be followed as shown.
4. Unit must be grounded to the metal frame of the mobile home.
CAUTION: This appliance must be vented to the outside.
Due to high temperatures, the stove should be placed out of
trafc and away from furniture and draperies.
Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns to
skin and/or clothing.
Young children should be carefully supervised when they are in
the same room as the stove.
Clothing and other ammable materials should not be placed
on or near this unit.
Installation
Minimum Size oor protection (USA) is 32
1/2
" wide By
33" deep (825mm X 838mm).
* Floor protection dimensions for the front and sides
are measured from the appliance door opening in
The United States. In Canada, the side dimension is
measured from the widest part of the appliance.
NOTE:
Measurement "L"
is measured from
the pedestal base
in the US ONLY
NOTE:
Measurement "K"
is measured from
the glass in the
US ONLY
L
J
Floor Protection
Requirements
US
Canada
Sides
Rear
6" 200mm
6" 200mm
K
Front
6" 450mm
THE STRUCTURAL INTEGRITY OF THE
MANUFACTURED HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
WARNING
DO NOT INSTALL IN SLEEPING ROOM.
Fig. 3
9"(228mm)With or W/Out Side Shields
9"(228mm)
9"(228mm)
Alternate floor protector
dimension may be used
as long as they satisfy the
measurement requirements
shown below.
Minumum size oor protection
for a corner installation hearth
pad is 36" x 36". Clearance
shown as 9" with optional side
shields installed.
Fig. 4
2"(51mm)
36"(914mm)
10" (254mm) with
side shields
16" (406mm)
without side shields
10" (254mm)
16" (406mm)
J
USA
K
L
J
CANADA
Floor protector

Other manuals for Harman P43

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P43 and is the answer not in the manual?

Harman P43 Specifications

General IconGeneral
Fuel TypePellet
IgnitionAutomatic
ThermostatYes
Heating AreaUp to 2, 200 sq ft
BlowerYes
WarrantyLimited

Related product manuals