EasyManua.ls Logo

Harman P43 - User Manual

Harman P43
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Harman® • P-Series Owner’s Manual_R10 • 2014 - ___ • 11/151 3-90-436168c
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your local dealer with questions on installation, operation or service.
Please read this entire manual before
installation and use of this pellet fuel-
burning room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Donotstoreorusegasolineorotherammablevapors
andliquidsinthevicinityofthisoranyotherappliance.
• Donotoverre-Ifanyexternalpartstartstoglow,you
areoverring.Reducefeedrate.Overringwillvoid
yourwarranty.
• Complywithallminimumclearancestocombustibles
asspecied.Failuretocomplymaycausehousere.
Hot glass will cause burns.
• Donottouchglassuntilitiscooled
• NEVERallowchildrentotouchglass
• Keepchildrenaway
• CAREFULLYSUPERVISEchildreninsameroomas
stove.
• Alertchildrenandadultstohazardsofhightemperatures.
High temperatures may ignite clothing or other
ammable materials.
• Keepclothing,furniture,draperiesandotherammable
materialsaway.
HOT SURFACES!
Glass and other surfaces are hot
duringoperationANDcooldown.
To obtain a French translation of this manual, please
contactyourdealerorvisitwww.harmanstoves.com
Pourobtenirunetraductionfrançaisedecemanuel,s’il
vous plaît contacter votre revendeur ou visitez www.
harmanstoves.com
NOTE
WARNING
WARNING
Owners Manual
Care and Operation
Model(s):
P43, P61A & P68
Freestanding Pellet Stove
NOTICE: SAVE THESE INSTRUCTIONS
P43
Use&CareVideo
P61A
Use&CareVideo
P68
Use&CareVideo
Checkbuildingcodespriortoinstallation.
• InstallationMUSTcomplywithlocal,regional,stateand
nationalcodesandregulations.
• Contactlocalbuildingorreofcialsaboutrestrictions
andinstallationinspectionrequirementsinyourarea.
CAUTION
!
Testedandapprovedforwoodpelletsandoramixtureof
upto50%shelledeldcornmixedwithaminimumof50%
woodpellets,burningofanyothertypeoffuelvoidsyour
warranty.Whenburningpellet/cornblendsmorefrequent
cleaningsmayberequired.
CAUTION
!

Other manuals for Harman P43

Questions and Answers

  • M
    Monica WongAug 15, 2025
    Why Harman P43 Stove does not feed pellets?
    • A
      Austin LopezAug 15, 2025
      If your Harman Stove isn't feeding pellets, several factors could be at play. It could be due to: - An empty hopper. - Low firebox draft affecting the feeder circuit's sensing switch, which can be resolved by checking for closed doors or gasket issues. - Insufficient initial fuel or starting gel in the burn pot. - Obstructions in the hopper or feeder requiring removal of fuel and examination. - A failed feed motor.
  • A
    Amy JohnsonAug 18, 2025
    What to do if my Harman P43 Stove fire has gone out?
    • S
      Stephen WebbAug 18, 2025
      If the fire in your Harman stove has gone out, check the status light and consider these potential causes: - The hopper may be out of fuel. - The draft could be too low because of a blocked flue. - Something may be restricting fuel flow. - The hopper lid may not be closed properly. - The feed motor or combustion blower may have failed.
  • B
    bpadillaAug 21, 2025
    Why Harman P43 has partially burned pellets?
    • C
      Christine RowlandAug 21, 2025
      Partially burned pellets in your Harman stove can stem from several issues: - The feed rate might be excessively high. - The air to fuel mixture may be imbalanced; inspect the burn pot clean-out cover and air intake. - The burn pot or heat exchanger tubes could require cleaning. - It might also be a combination of all the above factors.
  • R
    Ronald MooreAug 25, 2025
    How to troubleshoot low heat output on a Harman P43 Stove?
    • A
      Alexandra ReynoldsAug 25, 2025
      If your Harman stove's heat output is low, consider these possible causes: - The feed rate may be set too low. - A gasket leak could be causing a draft that is too low. - The pellets being used might be of poor quality or damp.
  • C
    Cynthia DavenportAug 27, 2025
    Why is smoke coming out of the vent of my Harman P43?
    • S
      stevetrujilloAug 27, 2025
      Visible smoke exiting the vent of your Harman stove can be attributed to: - An air-fuel ratio that is too rich. - A feed rate that is too high. - A draft that is too low, possibly due to a gasket leak.
  • C
    Charles SmithAug 30, 2025
    What to do if my Harman P43 Stove shows 6 blinks?
    • D
      Dwayne HarrisAug 30, 2025
      If your Harman stove is showing 6 blinks, it indicates poor or incomplete combustion for over 25 minutes. To reset, turn the mode selector to "O" and then back to your desired mode. As an alternative, perform a manual reset by disconnecting the power cord for a few seconds, then reconnect it. If the error persists, contact your dealer.
  • C
    cohenleeSep 2, 2025
    How to fix smoke smell from Harman P43?
    • T
      Taylor GonzalezSep 2, 2025
      To address a smoke smell coming from your Harman stove, seal the vent pipe points and connection to the stove using silicone.
  • B
    brianperezSep 5, 2025
    What does 3 blinks mean on my Harman Stove?
    • O
      ochavezSep 5, 2025
      If your Harman stove is showing 3 blinks, it indicates that the ESP (Exhaust Sensing Probe) has failed, has a broken connection, or has gone out of range too many times. This requires a manual reset.
  • T
    Timothy HooperSep 8, 2025
    What does 5 blinks mean on my Harman P43 Stove?
    • M
      Michael BarajasSep 9, 2025
      If your Harman stove is showing 5 blinks in Igniter Auto Mode, it means the unit failed to light within the start cycle. To reset, turn the Mode Selector to 'O', then turn it back to your desired mode.
  • F
    fryechristineSep 12, 2025
    What does 4 blinks mean on my Harman Stove?
    • A
      Anthony AlvarezSep 12, 2025
      If your Harman stove is showing 4 blinks, it can occur only in Room Temp mode and indicates the Room Sensing Probe has failed or is not installed. If a Room Sensing Probe is then installed, the status light will automatically reset.

Summary

Welcome

Congratulations

A welcome message and introduction to the Harman P-Series pellet stove.

Limited Lifetime Warranty

Warranty Coverage

Details HHT's warranty coverage for appliances and components.

Warranty Period

Defines the duration of warranty coverage for different appliance parts.

Warranty Conditions

Outlines the required conditions for the warranty to remain valid.

Warranty Exclusions

Lists specific situations and damages not covered by the warranty.

Limitations of Liability

Specifies the extent of manufacturer liability regarding appliance defects.

Product Specific and Important Safety Information

Appliance Certification

Lists agency certifications and standards the appliance meets.

Mobile Home Approved

Details requirements for safe installation in manufactured homes.

Glass Specifications

Provides specifications for the appliance's ceramic glass.

Electrical Rating

Specifies the appliance's electrical requirements and compatibility.

BTU & Efficiency Specifications

Lists BTU output and efficiency ratings for different stove models.

General Information

Appliance Safety

General safety precautions for appliance operation.

Clear Space

Defines required clearances around the appliance for fire safety.

Control Explanation

Explains the function of the appliance's control panel features.

Fuel Specifications

Details approved fuel types, quality, and storage recommendations.

General Operating Information

Describes how the appliance operates in different modes.

Operating Instructions

Starting Your First Fire

Step-by-step guide for the initial fire-starting process.

Fire Characteristics

Describes the expected flame pattern for a properly adjusted fire.

Feed Rate Adjustment Instructions

How to adjust the fuel feed rate for optimal burning.

Ignition Cycles

Explains the appliance's ignition and blower cycles.

Automatic Ignition

Details the automatic ignition system and its operation.

Maintenance and Service

Proper Shutdown Procedure

Instructions for safely shutting down the appliance.

Quick Reference Maintenance Chart

A summary of recommended cleaning and inspection frequencies.

General Maintenance

Discusses fuel types and their impact on maintenance needs.

Glass Maintenance

Guidance on cleaning and replacing the stove's glass.

Burnpot Maintenance

Steps for cleaning and maintaining the burnpot.

Combustion Blower Chamber

Instructions for cleaning the combustion blower area.

Pellet Feeder Chamber

Steps for inspecting and cleaning the pellet feeder chamber.

Troubleshooting and Frequently Asked Questions

Error Code Description

Explains status light error codes and their meanings.

Frequently Asked Questions

Addresses common user queries and provides solutions.

Troubleshooting

Guides users through common operational problems and fixes.

Reference Material

Safety Reminders

Reinforces key safety practices for operating the stove.

Motor and Component Location

Identifies the location of key motors and safety devices.

Loss of Power

Discusses power loss procedures and battery backup options.

Emergency Manual Ignition

Provides instructions for manual ignition if the automatic system fails.

Service Parts

Lists available replacement parts for various stove models.

Contact Information

Provides contact details for support and dealer location.

Harman P43 Specifications

General IconGeneral
Fuel TypePellet
IgnitionAutomatic
ThermostatYes
Heating AreaUp to 2, 200 sq ft
BlowerYes
WarrantyLimited

Related product manuals