EasyManua.ls Logo

Harman P43 - Troubleshooting and Frequently Asked Questions; Error Code Description

Harman P43
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Harman® • P-Series Owner’s Manual_R10 • 2014 - ___ • 11/1521 3-90-436168c
6
Troubleshooting and Frequently Asked Questions
Status light error messages:
3 Blinks:IndicatesthattheESP(ExhaustSensingProbe)
hasfailed,hasabrokenconnection,orhasgoneoutofrange
toomanytimes.Thisrequiresamanualreset*.
4 Blinks: Can occur only in Room Temp Mode and
indicatesRoom Sensing Probefailedor not installed.If a
RoomSensingProbeistheninstalled,thestatuslightwill
automaticallyreset.
NOTE:Unitwillnotstartin"AUTO"withthisstatuserror.
5 Blinks (In Igniter Auto. Mode Only):Indicatesthattheunit
hasfailedtolightwithinthe36minutestartcycle.Toreset-
TurnModeSelectorto"OFF",thenturntoeithermodeagain.)
6 Blinks :Indicatesthatthecontrolhascalculatedpooror
incompletecombustionoccurringformorethan25minutes.
Asixblinkstatusmaybesetifthestoveisallowedtorunout
ofpellets.Toreset,turnmodeselectorto"OFF"thenback
ontothedesiredmode.Iftheunitwasnotoutofpellets,see
Troubleshootingsectionformoredetails.
* Manual reset-disconnectpowercordforafewseconds
andreconnect.IferrorstilloccurscallyourDealer.
A. Error Code Description

Other manuals for Harman P43

Related product manuals