The Low Draft Pressure Switchisadifferentialpressureswitch
that monitors the negative pressure (Draft) in the rebox. If the
draftbecomestoo low forpropercombustion,the switch opens,
cuttingpowertothefeedmotorandtheignitercircuits.Thisswitch
isconnectedintotheAC(highvoltage)wiring.
The Control Board/ESP combination is responsible for all high
limitsafetycontrol.Thereare2highlimits,onenormaloperation
highlimitandonebackuphighlimit.Thecontrolhasanautomatic
diagnosticcircuitthatcontinuouslymonitorstheESPand Room
Sensorforfaults.Ifafaultshouldoccur,thecontrolsendsastatus
alertandatthesametimetheunitgoesdowntominimumfeed/
minimumburnasasafetycondition.
Backdraft Damper Assembly
Always check to see if the damper
plate swings freely inward and that
the seating edges are not covered
withdirtorlint.
Low Draft Pressure Switch
Feed Motor
Combustion Motor
B. Motor and Component Location
P-Series Pellet Stove Safety Devices
Distribution Blower

Other manuals for Harman P43

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman P43 and is the answer not in the manual?

Harman P43 Specifications

General IconGeneral
Fuel TypePellet
IgnitionAutomatic
ThermostatYes
Heating AreaUp to 2, 200 sq ft
BlowerYes
WarrantyLimited

Related product manuals