PA module operates into is a complex im-
pedance, with the resistive part being ap-
proximately 7 ohms per PA module.
Sliding the tap towards the ground end of
L2 will result in heavier loading of the PA.
D.2.2.5. L1 Tap
L1 sets the reactive componentthat thePA
modules should operate into. The PA nor-
mally sees anegative reactancewith a value
depending on frequency and performance
related conditions.
D-2 888-2314-001
WARNING: Disconnect primary power prior to servicing.