What to do if the internal electrical protection has tripped on my Hartridge HK900 Test Equipment?
- JjoshuamartinezAug 2, 2025
If the internal electrical protection of your Hartridge Test Equipment has tripped, first reset the unit by switching it off, waiting a few seconds, and then switching it back on. If it trips again, switch off the equipment, disconnect the injector cable, and switch it back on. The trip could be caused by a faulty injector coil or piezo, or by a fault within the AE32. To identify a faulty injector, test the injectors one at a time.