EasyManua.ls Logo

Hatz 2L41C - Emergency Start

Hatz 2L41C
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2L41C, 2M41, 2M41Z Faults
HATZ
89Operator’s Manual
Type of fault Possible causes Remedy Chapter
The speed ad-
justment lever
does not stay in
the desired posi-
tion.
Block the speed
adjustment.
The engine loses
power and speed,
and black smoke
emerges from the
exhaust.
Dirty air filter unit. Check the degree
of dirt contamina-
tion of the air filter,
and clean or renew
it if necessary.
8.2.10 Main-
taining the
dry air filter,
page 68
Tappet clearance
not OK.
Adjust the tappet
clearance.
8.2.12
Check and
set the tap-
pet clear-
ance, page
72
Injection nozzle is
not functional.
Contact Hatz ser-
vice.
Engine becomes
very hot.
Indicator lamp for
the cylinder head
temperature (addi-
tional equipment)
lights up.
Too much engine
oil in the engine.
Drain the engine oil
to the upper mark
of the dipstick.
7.8 Check-
ing the oil
level and
adding oil if
necessary,
page 47
Inadequate cool-
ing:
Contamination in
the entire area of
the cooling air
guides.
Clean the cooling
air area.
8.2.6 Clean-
ing the cool-
ing fan,
cooling fins
and oil
cooler, page
61
Incompletely
closed air guide
parts or capsule
parts.
Check the air guide
parts and shafts for
completeness and
good sealing prop-
erties.
9.2 Emergency start
Electrical automatic shutoff (additional equipment)
The distinguishing feature of the electrical automatic shutoff is brief flashing
of all indicators after turning the starting key to position "I".