G
- Technical characteristics
4 - AS - CE standard specificities
The following tests must be performed after :
• A major technical intervention.
• An accident due to major component failure on the machine.
4.1 - OVERLOAD TEST
Load table
4.2 - FUNCTIONAL TEST
Functional tests have confirmed the following: :
• The machine has performed all movements without jerking, while carrying the nominal load.
• All security systems are operating correctly.
• Maximum authorized operating speeds are not exceeded.
• The following tests must be performed by a qualified person in secure conditions.
• The results must be fully recorded.
To avoid the machine tipping over, it must be secured during the test (by a chain or anchorage point).
Machine Test load
Pound (lb) Kilogramme (kg)
COMPACT 8 (COMPACT 2032E)
COMPACT 14 (COMPACT 3947E)
965 437,5
COMPACT 8W (COMPACT 2247E)
COMPACT 10 (COMPACT 2747E)
COMPACT 12RTE (COMPACT 3368RTE)
1240 562,5
COMPACT 10N (COMPACT 2632E)
OPTIMUM 8 (OPTIMUM 1930E)
634 287,5
COMPACT 10N-1 (NA)
OPTIMUM 8-1 (NA)
331 150
COMPACT 12 (COMPACT 3347E)
COMPACT 8CU (NA)
827 375
OPTIMUM 6 (OPTIMUM 1530E) 744 337,5
COMPACT 10RTE (COMPACT 2668RTE) 1557 706,25
The machine must not show any signs of permanent distortion.
Tests are performed by a qualified person under optimal conditions and results must be fully recorded.