EasyManua.ls Logo

Haworth Hop TS User Manual

Haworth Hop TS
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
H
S
M
1
M2
Part No:
Rev:
Page:
E.C.O. No:
1 OF 10
CUSTOMER SERVICE PHONE: 1-800-426-8562
x1
HOP - TROUBLESHOOTING GUIDE
Identify Parts
Installation Instructions
Hop TSxxx-xxx
H
S
M1
M2
Standard Up/Down Hand SwitchProgrammable Hand Switch
Dual Stage - 3 Leg
Control Box
Dual Stage - 2 Leg
Control Box
Single Stage - 2 Leg
Control Box
OROR
OR
Leg 1
Slave
Leg
Motor Cord 1
Leg 2
Leg 1 Leg 3Leg 2
A
BB
H
S
M
1
C C
HS
M1
Leg 1
B
A
1
1
2
3
S
Motor
Cord 1
Motor
Cord 2
Motor
Cord 3
C
Motor Cord 2
Motor
Cord 1
Question and Answer IconNeed help?

Do you have a question about the Haworth Hop TS and is the answer not in the manual?

Haworth Hop TS Specifications

General IconGeneral
BrandHaworth
ModelHop TS
CategoryIndoor Furnishing
LanguageEnglish

Summary

Troubleshooting Error Codes

Hot Error

Overheating has caused it to stop the Control Box. Let Control Box cool down.

Internal Errors (E00-E02)

M1, M2, or M3 internal errors. Pull plug and replace controller box.

Defective Errors (E12-E14)

M1, M2, or M3 defective. Replace leg/motor.

Over-Current Errors (E24-E26)

M1, M2, or M3 over-current. Unload table.

Connection Errors (E12-E14)

Errors E12, E13, or E14 with no connection. Check connections.

Noise Troubleshooting

Noise caused by loose hex rod. Tighten hex rod.

Initializing New and Existing Tables

Collision and Over-Current Errors

Collision Error Resolution

Remove obstruction to resolve collision.

Stage Leg Calibration

Single stage leg calibration is initializing; dual stage leg calibration is initializing.

Over-Current Error Resolution

Max load exceeded indicates an over-current error. Unload table.

Container Stop and Shelf Stop Functions

Add Container/Shelf Stop

Set desired height and press buttons until two clicks are heard.

Remove Container/Shelf Stop

Press and hold buttons until one click is heard.

Reset Control Unit to Factory Settings

Specific Error Code Troubleshooting (E12-E26)

Error Code Identification

Check hand switch for error code and identify column leg and control box.

Connector Swapping Procedure

Swap connectors (M1 & M2) as shown for troubleshooting.

Error Code Diagnosis

Diagnose bad control box for E12/E24 or bad leg for E13/E25.

Single Stage Leg Calibration

Leg Leveling for Calibration

Ensure both legs are level before installing gear connector rod.

Gear Connector Rod Installation

Adjust and tighten gear connector rod, ensuring full seat.