03/18 Model 7501/7501T/7501T240 Page 1 of 8
No. 2080045(16)
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail: haws@hawsco.com website: www.hawsco.com
Model 7501/7501T/7501T240
Portable Eyewash/Portable Eyewash with Heater
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that this specific product is guaranteed against defective material or poor
workmanship for a period of one year from date of shipment. HAWS liability under this
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any
goods, or part thereof, which shall appear to the Company upon inspection to be of
defective material or not of first class workmanship, provided that claim is made in writing
to Haws within a reasonable period after receipt of the product. Where claims for defects
are made, the defective part or parts shall be delivered to the Company, prepaid, for
inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or
for any expense connected therewith made by the owner or his agents, except upon
written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages
caused by defective materials or poor workmanship, except for replacements
, as
provided above. Buyer agrees that Haws has made no other warranties either expressed
or implied in addition to those above stated, except that of title with respect to any of the
products or equipment sold hereunder and that HAWS shall not be liable for general,
special, or consequential damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and maintenance instructions provided are adhered to. The units also must be used for
the purpose for which they were intended. This product is intended to supplement first-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will prevent serious injury or the aggravation of existing or prior
injuries
.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF
THIS MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297

Other manuals for Haws 7501

Questions and Answers

  • L
    Lindsey CooperAug 20, 2025
    Why doesn't my Haws Security Sensors heater turn on?
    • D
      donaldcarpenterAug 20, 2025
      If your Haws Security Sensors heater isn't turning on, first ensure it's properly plugged in and that the outlet has power. For model 7501T, check the GFCI plug and circuit breaker. Also, if the ambient temperature is too high, preventing the blanket temperature from dropping below 67°F (19°C), the heater might not activate. The thermostat is preset to turn on at 67°± 5°F (17°± 3°C) and off at 77°± 5°F (25°± 3°C). You can test the thermostat by applying ice for 3-5 minutes; the heat trace cable should warm up if it's working correctly.
  • J
    Jennifer VillarrealAug 22, 2025
    What to do if water is leaking from Haws Security Sensors eyewash heads?
    • S
      Steven HendersonAug 22, 2025
      If you notice water leaking from the eyewash heads of your Haws Security Sensors, check if the water level exceeds the fill line indicated on the side of the unit and remove any excess water until it reaches the fill line. Also, ensure the unit is level from front to back and left to right.
  • S
    Sean DeanAug 25, 2025
    How to fix poor flow from Haws Security Sensors eyewash head(s)?
    • C
      cyatesAug 25, 2025
      To address poor flow from the eyewash head(s) in your Haws Security Sensors, try the following: a. Tighten the head assembly. b. Check for any obstructions. If necessary, remove the eyewash head(s), clean them, and reassemble. To reassemble, put the cap screw through the head and thread it into the head anchor two or three turns. Tilt the head assembly and work the anchor legs into the eyewash armholes, then tighten the assembly and check for leaks.
  • A
    andrea67Aug 26, 2025
    Why does Haws Security Sensors eyewash flow for less than 15 minutes?
    • H
      hjacksonAug 26, 2025
      If your Haws Security Sensors eyewash flows for less than 15 minutes, ensure the water level in the eyewash tank is filled to the water fill line indicated on the side of the unit.
  • T
    Terry YatesAug 27, 2025
    How to stop a water leak between joints or fittings on Haws Security Sensors?
    • J
      Joshua ClarkAug 27, 2025
      If you have a water leak between the joints or fittings of your Haws Security Sensors, a. Pull the hose off the fitting and smooth any raised plastic edge on the center of the fitting. Then, return the hose and hose clamp to their original positions. b. Tighten the hose clamp(s) with pliers.
  • J
    Jonathan FaulknerAug 29, 2025
    How to troubleshoot no flow in Haws Security Sensors?
    • T
      timothyboyleAug 29, 2025
      If there is no flow in your Haws Security Sensors, the tank may be empty. Refill the tank with 8.75 gallons of water. Alternatively, there might be an obstruction in the line or fitting; clear any obstruction.
  • R
    Ryan GonzalesAug 31, 2025
    What causes excessive water loss in Haws Security Sensors?
    • S
      Shawn OwensAug 31, 2025
      To address excessive water loss in your Haws Security Sensors, check the unit for leaks. Note that some water loss due to evaporation is normal.
  • L
    Lance PadillaSep 2, 2025
    What to do if there is a water leak between joints or fittings in Haws Medical Equipment?
    • A
      Amber MaySep 2, 2025
      If you experience water leaks between joints or fittings in your Haws Medical Equipment, first, smooth the raised plastic edge on the center of the fitting and return the hose and hose clamp to their original position. If the leak persists, use pliers to tighten the hose clamps.
  • L
    Lacey ChandlerSep 4, 2025
    How to fix no flow in Haws Medical Equipment?
    • K
      Kelsey ElliottSep 4, 2025
      If your Haws Medical Equipment has no flow, the tank might be empty. Refill the tank. Alternatively, there could be an obstruction in the line or fitting, so clear any obstructions.
  • M
    Matthew VelasquezSep 6, 2025
    What to do if my Haws Personal Care Product has no flow?
    • P
      Patricia PatelSep 6, 2025
      If there is no flow in your Haws Personal Care Product, the tank might be empty, so refill it with 8.75 gallons. Alternatively, there could be an obstruction in the line or fitting, so clear any obstructions.

Summary

Limited Warranty Information

Warranty Terms and Conditions

Details Haws' warranty for defective material or poor workmanship, excluding consequential damages.

Installation Instructions Overview

Recommended Tools and Location

Lists tools for installation and specifies ideal unit placement for accessibility and safety.

Electrical Connection and Ambient Ratings

Details power requirements, voltage, current, and acceptable operating temperature ranges for models.

Step-by-Step Installation Guide

Initial Setup and Mounting Procedures

Covers blanket installation, unit mounting for different models, and ensuring correct leveling.

Filling, Powering, and Safety

Instructions on filling the unit, energizing heated models, and critical electrical safety requirements.

Operating and Maintenance Procedures

Emergency Eyewash Operation Steps

Guides users on how to properly use the eyewash station during an emergency.

Routine Maintenance and Fluid Quality

Details inspection schedules, preventing bacteria, and procedures for refilling eyewash tanks.

Troubleshooting Common Issues

Repair Checklist for Problems

Provides solutions for common issues like no flow, poor flow, leaks, and heater malfunctions.

Parts Breakdown and Identification

Component List and Part Numbers

Itemized list of all replaceable parts with corresponding part numbers for ordering.

Haws 7501 Specifications

General IconGeneral
Model7501
CategoryPersonal Care Products
Flow Rate0.4 GPM
ComplianceANSI Z358.1
Product TypeEmergency Eye Wash
MountingWall Mount
MaterialPolyethylene
TypeEmergency Eyewash