03/18 Model 7501/7501T/7501T240 Page 1 of 8
No. 2080045(16)
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
E-mail: haws@hawsco.com website: www.hawsco.com
Model 7501/7501T/7501T240
Portable Eyewash/Portable Eyewash with Heater
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that this specific product is guaranteed against defective material or poor
workmanship for a period of one year from date of shipment. HAWS liability under this
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any
goods, or part thereof, which shall appear to the Company upon inspection to be of
defective material or not of first class workmanship, provided that claim is made in writing
to Haws within a reasonable period after receipt of the product. Where claims for defects
are made, the defective part or parts shall be delivered to the Company, prepaid, for
inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or
for any expense connected therewith made by the owner or his agents, except upon
written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages
caused by defective materials or poor workmanship, except for replacements
, as
provided above. Buyer agrees that Haws has made no other warranties either expressed
or implied in addition to those above stated, except that of title with respect to any of the
products or equipment sold hereunder and that HAWS shall not be liable for general,
special, or consequential damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and maintenance instructions provided are adhered to. The units also must be used for
the purpose for which they were intended. This product is intended to supplement first-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will prevent serious injury or the aggravation of existing or prior
injuries
.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF
THIS MODEL PLEASE CALL:
TECHNICAL SUPPORT: 1-800-766-5612
FOR CUSTOMER SERVICE: 1-888-640-4297

Other manuals for Haws 7501

Questions and Answers

  • T
    Tyler KellerSep 8, 2025
    What to do if water is leaking from the eyewash heads of my Haws Personal Care Product?
    • C
      Carolyn MarshallSep 8, 2025
      If water is leaking from the eyewash heads, it could be because the water level has exceeded the fill line indicated on the side of the unit; remove excess water until the fill line is reached. Also, ensure the unit is level from front to back and left to right.
  • P
    Patrick FordSep 9, 2025
    How to fix poor flow from eyewash heads in Haws 7501 Personal Care Products?
    • A
      Angela JacksonSep 10, 2025
      To fix poor flow from the eyewash head(s), begin by tightening the head assembly. Then, check for any obstructions. If obstructions are found, remove the eyewash head(s), clean them, and reassemble. To reassemble the head, put the cap screw through the head and thread it into the head anchor two or three turns. Tilt the head assembly and work the anchor legs into the eyewash armholes. Tighten the assembly and check for leaks.
  • A
    Aaron WillisSep 12, 2025
    Why does the eyewash of my Haws Personal Care Product flow for less than 15 minutes?
    • J
      Jennifer NewmanSep 12, 2025
      The eyewash may flow for less than 15 minutes if the water level in the eyewash tank is not filled to the water fill line indicated on the side of the unit. Fill the water to the indicated line.
  • S
    Sandra WarrenSep 13, 2025
    What to do if there is a water leak between joints or fittings in my Haws Personal Care Product?
    • T
      Timothy TaylorSep 13, 2025
      If you notice a water leak between the joints or fittings, pull the hose off the fitting and smooth any raised plastic edges on the center of the fitting. Then, return the hose and hose clamp to their original positions. You may also need to tighten the hose clamp(s) with pliers.
  • E
    elliottvictoriaSep 15, 2025
    What to do if the heater doesn’t turn on in my Haws Personal Care Product (Model 7501T/7501T240)?
    • C
      Curtis HughesSep 15, 2025
      If the heater doesn’t turn on, first check if the unit is plugged in or if there is power to the plug. Check the GFCI and circuit breaker (7501T only). Also, if the ambient temperature is high and doesn’t allow the water temperature to drop below 68°F (20°C), test the thermostat and heater function by applying ice in a circular motion to the thermostat location for approximately 3-5 minutes. The heat trace cable should become warm to the touch when operating properly.
  • L
    Laura BurnettSep 18, 2025
    Why is there excessive water loss from my Haws Personal Care Product?
    • A
      Alexandria GarciaSep 18, 2025
      If you observe excessive water loss, check the unit for leaks. Note that some water loss due to evaporation is normal.

Summary

Limited Warranty Information

Warranty Terms and Conditions

Details Haws' warranty for defective material or poor workmanship, excluding consequential damages.

Installation Instructions Overview

Recommended Tools and Location

Lists tools for installation and specifies ideal unit placement for accessibility and safety.

Electrical Connection and Ambient Ratings

Details power requirements, voltage, current, and acceptable operating temperature ranges for models.

Step-by-Step Installation Guide

Initial Setup and Mounting Procedures

Covers blanket installation, unit mounting for different models, and ensuring correct leveling.

Filling, Powering, and Safety

Instructions on filling the unit, energizing heated models, and critical electrical safety requirements.

Operating and Maintenance Procedures

Emergency Eyewash Operation Steps

Guides users on how to properly use the eyewash station during an emergency.

Routine Maintenance and Fluid Quality

Details inspection schedules, preventing bacteria, and procedures for refilling eyewash tanks.

Troubleshooting Common Issues

Repair Checklist for Problems

Provides solutions for common issues like no flow, poor flow, leaks, and heater malfunctions.

Parts Breakdown and Identification

Component List and Part Numbers

Itemized list of all replaceable parts with corresponding part numbers for ordering.

Haws 7501 Specifications

General IconGeneral
Model7501
CategoryPersonal Care Products
Flow Rate0.4 GPM
ComplianceANSI Z358.1
Product TypeEmergency Eye Wash
MountingWall Mount
MaterialPolyethylene
TypeEmergency Eyewash