Instructio nsforDEX2420MAR2ManualAirReliefValve ISDE2420MAR2
READ,UNDERSTANDANDFOLLOWALLSAFETYANDOPERATION
INSTRUCTI ONS
PRESSUREHAZARD
Poolandspawatercirculationsystemsoperateunder
hazardouspressureduringstartup,normaloperation,andafter
pumpshutoff.
· Standclearoffilterduringpumps tartup.
· Failuretofollowsafetyandoperationinstructionscouldresult
inviolentseparationoftheupperfilterbodyand/ormanualair
reliefvalveassembly duetopressureinsystem,whichcould
causepropertydamage,severepersonalinjuryordeat h.
STEPSTOPREVENTEXCESSIVEPRESSUREBUILDUPIN
SYSTEM
· Beforeservicingpoolandspawatercirc ulationsystemall
systemandpumpcontrolsmustbeinoffpositionandfilter
manualairreliefvalvem ustbeinopenposition.
· Beforestartingsys tempumpallsystemvalvesmustbesetina
positiontoallowsyst emwatertoreturnbacktothepool.Do
notchangefiltercontrolvalvepositionwhilesystempumpis
running.
· Beforestartingsys tempumpfullyopenfiltermanualair relief
valve,donotclosemanualairreliefvalveuntilasteadystream
ofwater(notair orairandwater)isdischarged.
FILTERCOMPONENT
SEPARATIONHAZARD
Failuretofollowsafety andoperationinstructionscouldresult
inviolentseparationoffi ltercomponents.
· Upperandlowerfilterbodiesmustbeproperlysecuredwith
filterbodyclamp.
· Beforeservicingpoolandspacirculationsystem,manualair
reliefvalvemustbeinopenposition.Donotoperatepooland
spacirculationsystemifasystemcomponentisnotassembled
properly,damagedormissing.
· Donotoperatepoolandspacirculationsystemunlessfilterair
reliefvalvebodyisinlocked“LOCK”positioninfilterupper
body.
Instructio ns
REMOVINGTHEMANUALAIRRELIEFVALVE
YourFiltercomeswiththeManualAirReliefValve(MAR)pre
installedfromthefactory.Onlyqualifiedpool professionals
shouldserviceyourfilter’sManualAirReliefValve.For
Qualifiedpoolprofessionalsonly:IffilterMARvalveneedsto
bereinstalled,followthisinstructioncarefully.
1. ShutoffPump
2. OpenMARValvetoopenpositi ontorelievepress ure.
3. GrasptheMARbodyattheflats,turntheMAR
counterclockwise(asthearrowindicated)untilthenotchonthe
ontheMARflangeisalignedwit hthe“UNLOCK”positionas
shownonthefilterhead.
4. PullouttheMARcarefully.
REINSTALLATION
1. AlignthenotchintheMARFlangewithnotchontheMARpart
ofthefilterh ead.
2. TurntheMARclockwise( asthearrowindic ates)untilthenotch
isalignedwiththe“LOCK”positionasshownonthefilt erhead.
3. Closefilterdrain.
4. Openallsystemvalvest oallowwaterflowfromfiltertopool
andpoolt opump/filtersystempriortostartingsystem.
5. Openfiltermanualairreliefvalvetofullopenpositiontoallow
airevacuationf romfilterduringsystemstartup.
6. StandClearofsystemduringsystemstartup.
7. Closefiltermanual airreliefvalvewhenasteadystreamof
water,notairandwatermix,isdischargedfromfiltermanualair
reliefvalve.
REPLACEMENTPARTS
1 DEX2420MAR2
MANUALAIRRELIEF
ASSEMBLY
2 CCX1000V
MANUALAIRRELIEFVALVE
WITHORING
3 CCX1000N
MANUALAIRRELIEFVALVE
NUT
4 DEX2420Z8A ORINGKIT(SETOF2)
5 ECX2712B1 PRESSUREGAUGE
Basicsafetyprecautionsshouldalways befollowed,includingthefollowing:Failuretofollowinstructi onscancausesevereinjuryand/or
death.
Thisisthesaf etyalertsymbol.Whenyouseethissymbolonyourequipmentorinthismanual,lookforoneofthefollowingsignal
wordsandb ealerttothepotentialforpersonalinjury.
warnsabouthazardsthatcouldcauseseriouspersonalinjury,deathormaj orpropertydamag eandif
ignoredpresents apotentialhazard.
warnsabouthazardsthatwillorcancauseminorormoderatepersonal injuryand/orpropertydamageand
ifignoredpresentsapotentialhazard.Itcanalsomakeconsumersawareofactionsthatareunpredictableandunsafe.
TheNOTICElabelindicatesspecialinstructionsthatareimportantbutnotrelatedtohazards.
Question and Answer IconNeed help?

Do you have a question about the Hayward DEX2420MAR2 and is the answer not in the manual?

Hayward DEX2420MAR2 Specifications

General IconGeneral
ModelDEX2420MAR2
Filter TypeCartridge
Flow Rate120 GPM
Filter Area240 sq. ft.
Max Pool Size48, 000 gallons
Cartridge Quantity2
Operating Pressure50 PSI
Inlet Size2 inch
Outlet Size2 inch

Summary

Safety and Operation Instructions

Pressure Hazard Warnings

Steps to Prevent Excessive Pressure Buildup

Steps to prevent dangerous pressure buildup in pool and spa systems by ensuring proper valve and pump control.

Separation Hazard Warnings

Manual Air Relief Valve Procedures

Removing the Manual Air Relief Valve

Procedure for removing the Manual Air Relief Valve (MAR) from the filter head. Requires qualified professional.

Re-installation of Manual Air Relief Valve

Procedure for re-installing the Manual Air Relief Valve (MAR) into the filter head, ensuring proper alignment and locking.

Related product manuals