USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5
WARNING–Failuretoremovepressuretestplugsand/orplugsusedinwinterizationofthepool/spa
fromthesuctionoutletscanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Failuretokeepsuctionoutletcomponentsclearofdebris,suchasleaves,dirt,hair,paper
andothermaterialcanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Suctionoutletcomponentshaveanitelife,thecover/grateshouldbeinspectedfre-
quentlyandreplacedatleasteverytenyearsoriffoundtobedamaged,broken,cracked,missing,ornot
securelyattached.
WARNING–AllsuctionanddischargevalvesMUSTbeOPENwhenstartingthecirculationsystem.
Failuretodosocouldresultinseverepersonalinjuryand/orpropertydamage.Alldrainsandsuction
outletsMUSThaveproperlyinstalledcovers,securelyattachedusingthescrewssuppliedwiththecov-
ers.Ifscrewsarelost,orderreplacementpartsfromyoursupplier.
WARNING Hazardous Pressure.Poolandspawatercirculationsystemsoperate
underhazardouspressureduringstartup,normaloperation,andafterpumpshutoff.
Standclearofcirculationsystemequipmentduringstartup.Failuretofollowsafety
andoperationinstructionscouldresultinviolentseparationofthepumphousing
andcoverduetopressureinthesystem,whichcouldcausepropertydamage,severe
personalinjury,ordeath.Beforeservicingpoolandspawatercirculationsystem,all
systemandpumpcontrolsmustbeinoffpositionandltermanualairreliefvalve
mustbeinopenposition.Beforestartingsystempump,allsystemvalvesmustbeset
inapositiontoallowsystemwatertoreturnbacktothepool.Donotchangelter
controlvalvepositionwhilesystempumpisrunning.Beforestartingsystempump,
fullyopenltermanualairreliefvalve.Donotcloseltermanualairreliefvalve
untilasteadystreamofwater(notairorairandwater)isdischarged.
WARNINGSeparation Hazard.Failuretofollowsafetyandoperationinstruc-
tionscouldresultinviolentseparationofpumpcomponents.Strainercovermustbe
properlysecuredtopumphousingwithstrainercoverlockring.Beforeservicing
poolandspacirculationsystem,manualairreliefvalvemustbeinopenposition.Do
notoperatepoolandspacirculationsystemifasystemcomponentisnotassembled
properly,damaged,ormissing.Donotoperatepoolandspacirculationsystemunless
lterairreliefvalvebodyisinlockedpositioninlterupperbody.
WARNING –Neveroperateortestthecirculationsystematmorethan40PSI.
WARNING–Fireandburnhazard.Motorsoperateathightemperaturesandiftheyarenotproperly
isolatedfromanyammablestructuresorforeigndebristheycancauseres,whichmaycausesevere
personalinjuryordeath.Itisalsonecessarytoallowthemotortocoolforatleast20minutespriorto
maintenancetominimizetheriskofburns.
WARNING–Failuretoinstallaccordingtodenedinstructionsmayresultinseverepersonalinjuryor
death.