HxxxFD(N/P)ASME
Universal H Series Heaters
Troubleshooting Guide
HxxxFD(N/P)
TSG-UHS16b
Copyright 2017 Hayward Industries Inc.

Other manuals for Hayward H150FDN

Questions and Answers

  • R
    Robert HinesAug 17, 2025
    What to do if my Hayward Heater shows 'Ignition Failure'?
    • D
      dianapetersonAug 17, 2025
      If your Hayward Heater is experiencing ignition failure, you should inspect the ignition system for faults.
  • R
    Riley HernandezAug 20, 2025
    What to do if my Hayward Heater displays a 'Communication Error Between Control Module and Display Interface Assembly'?
    • J
      Joseph BauerAug 20, 2025
      If your Hayward Heater shows a communication error between the control module and the display interface assembly, verify the connections between these components.
  • S
    Steven WhiteAug 22, 2025
    What to do if my Hayward Heater displays 'Temperature Sensor (thermistor) input failure'?
    • K
      kkochAug 22, 2025
      If your Hayward Heater shows a 'Temperature Sensor (thermistor) input failure', check the temperature sensor and replace it if necessary.
  • V
    vholmesAug 25, 2025
    What to do if my Hayward Heater shows 'Ignitor Circuit Open'?
    • A
      Angela BaileyAug 26, 2025
      If your Hayward Heater displays 'Ignitor Circuit Open', check the ignitor circuit for continuity.
  • O
    obartonAug 28, 2025
    What to do if my Hayward Heater indicates 'Keypad failure'?
    • M
      Melissa FergusonAug 28, 2025
      If your Hayward Heater indicates a 'Keypad failure', the solution is to replace the keypad.
  • C
    Christopher CampbellAug 30, 2025
    What to do if my Hayward Heater displays 'Maximum return water temperature exceeded and / or rapid water temperature rise'?
    • M
      Melody Barnett DVMAug 30, 2025
      If your Hayward Heater displays 'Maximum return water temperature exceeded and / or rapid water temperature rise', check the water temperature sensors and system settings.
  • S
    Steven AllisonSep 2, 2025
    What to do if my Hayward Heater shows 'Flame present with Gas Valve not energized'?
    • R
      Randy HarveySep 2, 2025
      If your Hayward Heater shows 'Flame present with Gas Valve not energized', check the gas valve and ignition system.
  • S
    Sarah WebsterSep 5, 2025
    What to do if my Hayward Heater displays 'Voltage polarity reversed, low voltage detected'?
    • K
      Kevin MarshSep 5, 2025
      If your Hayward Heater displays 'Voltage polarity reversed, low voltage detected', correct the polarity and ensure proper voltage is supplied.
  • W
    William WilliamsSep 8, 2025
    What to do if my Hayward Heater shows 'Water Pressure Switch, Vent Pressure Switch, or Temperature Limit Switch Fault'?
    • A
      Amy WilliamsSep 8, 2025
      If your Hayward Heater indicates 'Water Pressure Switch, Vent Pressure Switch, or Temperature Limit Switch Fault', inspect all associated switches for proper operation.
  • P
    pamelasmithSep 12, 2025
    What to do if my Hayward Heater displays 'Blower Vacuum Switch open'?
    • K
      Kristy WilsonSep 12, 2025
      If your Hayward Heater displays 'Blower Vacuum Switch open', inspect the blower vacuum switch for faults.

Hayward H150FDN Specifications

General IconGeneral
ModelH150FDN
Heating Capacity150, 000 BTU/hr
Fuel TypeNatural Gas
Efficiency82%
Warranty1 Year
TypePool Heater
Ignition TypeElectronic
Heat ExchangerCupro Nickel